EMS 日志报告 "scsi.cmd.notReadyCondition"
适用于
- FAS8200
- FAS9000
- FAS2750
- ONTAP 9
- X377_HLBRE10TA07
- X318_HLBRE08TA07 - 固件 NA00
- X318_HARHE08TA07 - 固件 NA01
问题描述
- 从 EMS 日志中可以确认以下输出。
- 暂时检测到
scsi.cmd.notReadyCondition
消息,后续重试已确认成功。
示例:
Wed Aug 06 05:03:58 +0900 [node_name: scsi_cmdblk_strthr_admin: scsi.cmd.checkCondition:error]: Disk device 0a.01.7: Check Condition: CDB 0x2f:1f78fc00:0400: Sense Data SCSI:no sense - (0x0 - 0x0 0x0 0x0)(31).
Wed Aug 06 05:03:58 +0900 [node_name: scsi_cmdblk_strthr_admin: scsi.cmd.adapterHardwareErrorEMSOnly:error]: Disk device 0a.01.7: Adapter detected hardware error: HA status 0xb: cdb 0x2f:1f78fc00:0400.
Wed Aug 06 05:04:18 +0900 [node_name: scsi_cmdblk_strthr_admin: scsi.cmd.notReadyCondition:notice]: Disk device 0a.01.7: Device returns not yet ready: CDB 0x88:00000001b86540c8:00000008: Sense Data SCSI:not ready - Drive spinning up (0x2 - 0x4 0x1 0x2)(19408).
Wed Aug 06 05:04:19 +0900 [node_name: scsi_cmdblk_strthr_admin: scsi.cmd.retrySuccess:debug]: Disk device 0a.01.7: request successful after retry #0/#11: cdb 0x28:071bfc90:0008 (20428).