问题

 

重新启动单个 ONTAP Select 实例后,未镜像的数据聚合将保持脱机状态。在 EMS 中可以看到以下内容:
 
03Jul2020 07:49:44 raid_capacity_license_alloc capacity="10239" capacity_unit="GB"mirrored="unmirrored" aggregate_name="aggr_data" aggregate_uuid="<UUID>" operation="Aggregate online" root="0" status="15" callback="1" sequence="0"
03Jul2020 07:49:44 raid_capacity_license_status status_string="allocation failed" aggregate_name="aggr_data" licensed_size="0" licensed_size_unit="MB" capacity_left="0" capacity_left_unit="MB" capacity_required="0" capacity_required_unit="MB" status_code="5" sequence="1"
03Jul2020 07:49:45 raid_assim_tree_offline vol_type="Aggregate" owner="" vol="aggr_data"reason="Licensing services are unavailable" instanceId="3583"
03Jul2020 07:49:47 raid_vol_state_changed vol_type="Volume" vol="aggr_data" state="offline"
03Jul2020 07:49:57 raid_mv_defVol_online_fail aggregate_name="aggr_data" reason="CR_ONLINE_ERROR"

 