跳转到主内容

检测到Brocade错误单个RDY帧丢失

Views:
130
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches
Specialty:
brocade
Last Updated:

状态信息

适用场景

  • 任何版本的 ONTAP
  • 任何版本的 Fabric OS ( FOS )

问题描述

  • 帧丢失警报
  • 基础架构移动后帧丢失警报

以下错误信息已登录errdump -a
CHASSIS, WARNING, Brocade6505, Single RDY/Frame Loss detected and recovered on Slot 0,Port 1(5) rdy(0xb)/frame(0x3f).

Portershow报告以下情况:

MCC-SWITCH1:admin> porterrshow 1

           frames      enc    crc    crc    pcs    uncor
        tx     rx      in    err    g_eof     err    err
  1:    3.6g   1.3g   0      2.0k   1.9k       207.1k  32.8k

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.