双端口 FCP SRAM DUMP 的定期通知
适用场景
- ONTAP 9.
- FCP
- Cisco交换机
问题描述
- 定期重置(称为 FCP 目标适配器的FCP 转储)会影响两个端口
Event Log
显示:
slifc_timeout_1: fci.device.quiesce:debug]: Adapter 1d encountered a command timeout on Disk device Switch x LUN y
slifc_timeout_1: fci.device.timeout:debug]: HBA 1d encountered a device timeout on Disk device Switch x LUN y
slifc_intrd: scsi.cmd.abortedByHost:error]: Disk device x Command aborted by host adapter
slifc_intrd: scsi.cmd.retrySuccess:debug]: Disk device z request successful after retry
fct_tpd_thread_6: scsitarget.fcp.dump:debug]: FCP target SRAM dump generated for adapter 10a, FW Initiated Dump
fct_tpd_thread_6: scsitarget.hwpfct.errorReset:notice]: An error was encountered in the FC target driver on Fibre Channel target adapter 10a. The adapter will be automatically reset to clear the status
fct_tpd_thread_7: scsitarget.hwpfct.errorReset:notice]: An error was encountered in the FC target driver on Fibre Channel target adapter 10b. The adapter will be automatically reset to clear the status
fct_tpd_thread_7: fcp.io.status:debug]: STIO Adapter 10b resetting with ITNs and commands to drain
fct_tpd_thread_7: scsitarget.fct.reset:notice]: Resetting Fibre Channel target adapter 10b.
fct_tpd_thread_6: scsitarget.hwpfct.dump.saved:notice]: A dump for adapter 10a was stored in /etc/log/abc.dmp.gz.
- 显示来自 Cisco 交换机的日志记录显示链接重置:
FC-xx %PORT-5-IF_DOWN_LINK_FAILURE: %$VSAN 1%$ Interface fc1/xx is down (Link failure loss of signal)
FC-xx %PORT-5-IF_UP: %$VSAN 1%$ Interface fc1/20 is up in mode F
FC-xx %PORT-5-IF_DOWN_LINK_FAILURE: %$VSAN 1%$ Interface fc1/xx is down (Link failure loss of signal)
FC-xx %PORT-5-IF_UP: %$VSAN 1%$ Interface fc1/xx is up