多个驱动器上的持续 SCSI 恢复错误
适用于
- ONTAP 9
- AFF/FAS 平台
- 驱动器
问题
- 多个磁盘上的多个恢复错误以及跨多个盘架和节点报告的盘架警告
[?] Thu Apr 02 08:17:58 +0200 [Node-01: disk_server_0: disk.ioRecoveredError.retry:info]: Recovered error on disk xxxx:10.126L91: op 0x28:00000008:0008 sector 1 SCSI:recovered error - Disk used internal retry algorithm to obtain data (1 b 96 96) (19) Disk netappFC100:10.126L91 Shelf 2 Drawer 3 Slot 4 Bay 28 [NETAPP X376_HLBRE08TA07 NA03] S/N [7SGR94NC] UID [5000CCA2:52288A0C:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000][?] Wed Feb 18 00:15:56 +0100 [Node-02: disk_server_0: disk.ioRecoveredError.retry:info]: Recovered error on disk xxxx:10.126L109: op 0x2a:5f265400:0200 sector 8 SCSI:recovered error - Disk used internal retry algorithm to obtain data (1 b 97 97) (45) Disk netappFC100:10.126L109 Shelf 2 Drawer 4 Slot 10 Bay 46 [NETAPP X376_HLBRE08TA07 NA03] S/N [7SGTZ45C] UID [5000CCA2:522D681C:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]
[Node-02:statd:monitor.shelf.warning:error]: Fault reported on disk storage shelf attached to channel xxxx:14. Check fans, power supplies, disks, and temperature sensors.
- 错误是信息性的/已恢复的,不是立即的硬件故障
- 磁盘具有高通电小时 (POH),许多超过 8 年的服务时间
- 所有盘架都有最新的 IOM 固件