跳转到主内容

禁用脱机SAS主机适配器和所有物理

Views:
4
Visibility:
Public
Votes:
0
Category:
aff-series
Specialty:
hw
Last Updated:

适用场景

  • AFF-A250
  • ONTAP 9.11.1

问题描述

  • 所有节点上的SAS主机适配器均显示脱机、所有端口的物理均显示已禁用
  • 系统不会重新对SAS卡固件和其他详细信息进行登录
  •  sysconfig -a  example:

::> system node run -node * -command sysconfig -a
slot 1: SAS Host Adapter 1a (Broadcom SAS3616W rev. 2, SAS, <OFFLINE (hard)>)
Firmware rev:      14.00.00.00
NVDATA rev:
Base WWN:          0:000000:0000000:00
Temperature:       Not Available
MFG Part Number:   111-04791
Board Name:
Assembly:
Serial number:
Phy State:         [0] Disabled
[1] Disabled
[2] Disabled
[3] Disabled
[4] Disabled
[5] Disabled
[6] Disabled
[7] Disabled
[8] Disabled
[9] Disabled
[10] Disabled
[11] Disabled
[12] Disabled
[13] Disabled
[14] Disabled
[15] Disabled

Mini-SAS HD Vendor:        not available
Mini-SAS HD Part Number:   not available
Mini-SAS HD Type:          not available
Mini-SAS HD Serial Number: not available

警告

更换/重新拔插SAS适配器卡需要接管节点、完成重新拔插或更换后、需要先进行恢复。
确保主机与节点具有冗余连接、并且MPIO已到位。
  • 重新拔插SAS适配器卡后问题描述仍保留 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.

 

  • 这篇文章对您有帮助吗?