断电后使聚合脱机
适用场景
- 所有FAS 和AFF 系统
- 所有 ONTAP 版本
- FlashPool
- 磁盘驱动器X446_PHM2200MCTO、固件低于NA05
- 磁盘驱动器X438_PHM2400MCTO、固件低于NA05
- 断电
问题描述
- 断电后、一个聚合脱机、无法联机
cluster::> storage aggregate modify -aggregate hybrid_aggregate -state online
Error: command failed: Failed to bring aggregate "hybrid_aggregate" online. Reason: Aggregate 'hybrid_aggregate' has failed and cannot be brought online.
- 聚合的SSD RAID组缺失
Aggregate hybrid_aggregate (failed, mixed_raid_type, partial, hybrid_enabled) (block checksums)
Plex /hybrid_aggregate/plex0 (offline, failed, inactive)
RAID group /hybrid_aggregate/plex0/rg0 (normal, block checksums, raid_dp)
RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks)
--------- ------ ------------- ---- ---- ---- ----- -------------- --------------
dparity 2b.11.4 2b 11 4 SA:B 0 SAS 10000 857000/1755136000 858483/1758174768
parity 0b.11.5 0b 11 5 SA:A 0 SAS 10000 857000/1755136000 858483/1758174768
data 2b.11.6 2b 11 6 SA:B 0 SAS 10000 857000/1755136000 858483/1758174768
data 0b.11.7 0b 11 7 SA:A 0 SAS 10000 857000/1755136000 858483/1758174768
Plex is missing 1 RAID group.
- 磁盘X446_PHM2200MCTO显示
Failed-Unsupported
在中SYSCONFIG-A
11.0 : NETAPP X446_PHM2200MCTO NA04 0.0GB 0B/sect (Failed-Unsupported)
11.1 : NETAPP X446_PHM2200MCTO NA04 0.0GB 0B/sect (Failed-Unsupported)
11.2 : NETAPP X446_PHM2200MCTO NA04 0.0GB 0B/sect (Failed-Unsupported)
11.3 : NETAPP X446_PHM2200MCTO NA04 0.0GB 0B/sect (Failed-Unsupported)
- 在发生故障之前、磁盘X446_PHM2200MCTO已打开电源超过70000小时(~8年)