适用场景
- DS224C
- 缺少单个磁盘架中的所有磁盘。
问题描述
- 磁盘架中无LED /电源活动
- 一个特定磁盘架中未报告磁盘
::> storage disk show -disk <stack>.<shelfID>.*
- 磁盘架日志中的冷启动消息。
Thu Jan 01 00:00:00 1970 ( 0+00:00:00.205); 02000093; U; HAL; hal; 04; Module Reboot: Startup type 1-Cold boo
- 高磁盘架温度传感器和消息:
Thu Jan 01 00:00:00 1970 ( 0+00:00:10.217); 0304002D; M; ENC_MGT; env_control; 04; Temperature zone 7 is now: warning hot set
Thu Jan 01 00:00:00 1970 ( 0+00:00:10.217); 0304002F; M; ENC_MGT; env_control; 04; Temperature zone 7 is now: critical hot set
...
Thu Jan 01 00:00:00 1970 ( 0+00:00:11.461); 0304002E; M; ENC_MGT; env_control; 04; Temperature zone 7 is now: warning hot cleared
Thu Jan 01 00:00:00 1970 ( 0+00:00:11.461); 03040030; M; ENC_MGT; env_control; 04; Temperature zone 7 is now: critical hot cleared