DS460磁盘架显示风扇不可用
适用场景
DS460-12磁盘架
问题描述
- 受影响磁盘架在环境中显示以下风扇状态:
::> system node run -node <nodename> -command environment status
Cooling Units by element:
[1] 5100 RPM
[2] 4500 RPM
[3] 5070 RPM
[4] 4500 RPM
[5] Unavailable<--
[6] Unavailable<--
[7] Unavailable<--
[8] Unavailable<--
- EMS日志显示以下消息
[Node-01: dsa_disc: ses.status.fanError:EMERGENCY]: DS460-12 (S/N XXXXXXXX) shelf X on channel 2d cooling fan error for Cooling element 8 7 6 5: critical status no redundancy. This module is on the rear of the shelf to the right.
[Node-01: dsa_disc: ses.status.fanError:EMERGENCY]: DS460-12 (S/N XXXXXXXX) shelf X on channel 2d cooling fan error for Cooling element 8 7 6 5: critical status no redundancy. This module is on the rear of the shelf to the right.
- 已更换风扇模块、但问题描述仍然存在