跳转到主内容

DS460磁盘架故障

Views:
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

适用于

DS460C 存储架

问题描述

在连接到通道 0b 的 DS460C 磁盘存储盘架 21 上报告了严重故障
 
EMS
Mon Aug 11 03:35:54 [node-1: statd: monitor.shelf.fault:alert]: Critical fault reported on disk storage shelf attached to channel 0b. Check fans, power supplies, disks, and temperature sensors.
Mon Aug 11 03:36:00 [node-1: monitor: monitor.globalStatus.critical:EMERGENCY]: Disk shelf fault.
Mon Aug 11 03:36:03 [node-1: dsa_worker5: ses.status.temperatureWarning:alert]: DS460-12 (S/N xxxxxxxxxxxxxxx) shelf 21 on channel 0b temperature warning for Temperature sensor 15: not installed or failed. Current temperature: 37 C (98 F). This module is on the front of the shelf 3rd drawer from the top, module A sensor 2.
Mon Aug 11 03:36:03 [node-1: dsa_worker5: ses.status.temperatureWarning:alert]: DS460-12 (S/N xxxxxxxxxxxxxxx) shelf 21 on channel 0b temperature warning for Temperature sensor 25: not installed or failed. Current temperature: 36 C (96 F). This module is on the front of the shelf 3rd drawer from the top, module B sensor 2.
 
存储故障
Enclosure Status: normal
Channel: 0b
Shelf: 21
Shelf Type: DS460-12
Product Serial Number: xxxxxxxxxxxxxxx
Module Type: IOM12B
 
Disk Elements:
Element Status          Status Bytes  Status Descriptions
0 [Bay  0]: NOT AVAILABLE   07,00,00,00
1 [Bay  1]: NOT AVAILABLE   07,01,00,00
2 [Bay  2]: NOT AVAILABLE   07,02,00,00
3 [Bay  3]: NOT AVAILABLE   07,03,00,00
4 [Bay  4]: NOT AVAILABLE   07,04,00,00
5 [Bay  5]: NOT AVAILABLE   07,05,00,00
6 [Bay  6]: NOT AVAILABLE   07,06,00,00
7 [Bay  7]: NOT AVAILABLE   07,07,00,00
8 [Bay  8]: NOT AVAILABLE   07,08,00,00
9 [Bay  9]: NOT AVAILABLE   07,09,00,00
10 [Bay 10]: NOT AVAILABLE   07,0A,00,00
11 [Bay 11]: NOT AVAILABLE   07,0B,00,00
12 [Bay  0]: OK         01,00,00,00
13 [Bay  1]: OK         01,01,00,00
14 [Bay  2]: OK         01,02,00,00
15 [Bay  3]: OK         01,03,00,00
16 [Bay  4]: OK         01,04,00,00
17 [Bay  5]: OK         01,05,00,00
18 [Bay  6]: OK         01,06,00,00
19 [Bay  7]: OK         01,07,00,00
20 [Bay  8]: OK         01,08,00,00
21 [Bay  9]: OK         01,09,00,00
22 [Bay 10]: OK         01,0A,00,00
23 [Bay 11]: OK         01,0B,00,00
24 [Bay  0]: OK         01,00,00,00
25 [Bay  1]: OK         01,01,00,00
26 [Bay  2]: OK         01,02,00,00
27 [Bay  3]: OK         01,03,00,00
28 [Bay  4]: OK         01,04,00,00
29 [Bay  5]: OK         01,05,00,00
30 [Bay  6]: OK         01,06,00,00
31 [Bay  7]: OK         01,07,00,00
32 [Bay  8]: OK         01,08,00,00
33 [Bay  9]: OK         01,09,00,00
34 [Bay 10]: OK         01,0A,00,00
35 [Bay 11]: OK         01,0B,00,00
36 [Bay  0]: OK         01,00,00,00
37 [Bay  1]: OK         01,01,00,00
38 [Bay  2]: OK         01,02,00,00
39 [Bay  3]: OK         01,03,00,00
40 [Bay  4]: OK         01,04,00,00
41 [Bay  5]: OK         01,05,00,00
42 [Bay  6]: OK         01,06,00,00
43 [Bay  7]: OK         01,07,00,00
44 [Bay  8]: OK         01,08,00,00
45 [Bay  9]: OK         01,09,00,00
46 [Bay 10]: OK         01,0A,00,00
47 [Bay 11]: OK         01,0B,00,00
48 [Bay  0]: OK         01,00,00,00
49 [Bay  1]: OK         01,01,00,00
50 [Bay  2]: OK         01,02,00,00
51 [Bay  3]: OK         01,03,00,00
52 [Bay  4]: OK         01,04,00,00
53 [Bay  5]: OK         01,05,00,00
54 [Bay  6]: OK         01,06,00,00
55 [Bay  7]: OK         01,07,00,00
56 [Bay  8]: OK         01,08,00,00
57 [Bay  9]: OK         01,09,00,00
58 [Bay 10]: OK         01,0A,00,00
59 [Bay 11]: OK         01,0B,00,00
 
Drawers Control Module:
Element Status            Status Bytes  Status Descriptions
1 [IOM12B A]   : CRITICAL      02,40,00,00  FAIL
2 [IOM12B A]   : OK         01,00,01,01  REPORT, TYPE BIT0
3 [IOM12B A]   : OK         01,00,01,01  REPORT, TYPE BIT0
4 [IOM12B A]   : OK         01,00,01,01  REPORT, TYPE BIT0
5 [IOM12B A]   : OK         01,00,01,01  REPORT, TYPE BIT0
6 [IOM12B B]   : CRITICAL      02,40,00,00  FAIL
7 [IOM12B B]   : OK         01,00,01,01  REPORT, TYPE BIT0
8 [IOM12B B]   : OK         01,00,01,01  REPORT, TYPE BIT0
9 [IOM12B B]   : OK         01,00,01,01  REPORT, TYPE BIT0
10 [IOM12B B]   : OK         01,00,01,01  REPORT, TYPE BIT0
 
环境
Temperature Sensor installed element list: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29; with error: none
Shelf temperatures by element:
[1] 20 C (68 F) (ambient)  Normal temperature range
[2] 29 C (84 F)  Normal temperature range
[3] 30 C (86 F)  Normal temperature range
[4] 30 C (86 F)  Normal temperature range
[5] 29 C (84 F)  Normal temperature range
[6] 31 C (87 F)  Normal temperature range
[7] 31 C (87 F)  Normal temperature range
[8] 32 C (89 F)  Normal temperature range
[9] 34 C (93 F)  Normal temperature range
[10] Unavailable
[11] 32 C (89 F)  Normal temperature range
[12] 31 C (87 F)  Normal temperature range
[13] 33 C (91 F)  Normal temperature range
[14] 32 C (89 F)  Normal temperature range
[15] Unavailable
[16] 33 C (91 F)  Normal temperature range
[17] 32 C (89 F)  Normal temperature range
[18] 32 C (89 F)  Normal temperature range
[19] 33 C (91 F)  Normal temperature range
[20] Unavailable
[21] 30 C (86 F)  Normal temperature range
[22] 31 C (87 F)  Normal temperature range
[23] 32 C (89 F)  Normal temperature range
[24] 31 C (87 F)  Normal temperature range
[25] Unavailable
[26] 32 C (89 F)  Normal temperature range
[27] 31 C (87 F)  Normal temperature range
[28] 30 C (86 F)  Normal temperature range
[29] 32 C (89 F)  Normal temperature range
 
DCM installed element list: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10; with error: 1, 6
DCM information by element:
[1] Serial number:  Part number:
Type:  Vendor:  Firmware version:
[2] Serial number: xxxxxxxxxxxx  Part number: 111-04834+A1
Type: SASDRWR  Vendor: NETAPP  Firmware version: 01310805
[3] Serial number: xxxxxxxxxxxx  Part number: 111-04834+A1
Type: SASDRWR  Vendor: NETAPP  Firmware version: 01310805
[4] Serial number: xxxxxxxxxxxx  Part number: 111-04834+A1
Type: SASDRWR  Vendor: NETAPP  Firmware version: 01310805
[5] Serial number: xxxxxxxxxxxx  Part number: 111-04834+A1
Type: SASDRWR  Vendor: NETAPP  Firmware version: 01310805
[6] Serial number:  Part number:
Type:  Vendor:  Firmware version:
[7] Serial number: xxxxxxxxxxxx  Part number: 111-04834+A1
Type: SASDRWR  Vendor: NETAPP  Firmware version: 01310805
[8] Serial number: xxxxxxxxxxxx  Part number: 111-04834+A1
Type: SASDRWR  Vendor: NETAPP  Firmware version: 01310805
[9] Serial number: xxxxxxxxxxxx  Part number: 111-04834+A1
Type: SASDRWR  Vendor: NETAPP  Firmware version: 01310805
[10] Serial number: xxxxxxxxxxxx  Part number: 111-04834+A1
Type: SASDRWR  Vendor: NETAPP  Firmware version: 01310805

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.

 

  • 这篇文章对您有帮助吗?