跳转到主内容

通过更换缆线解决了单个NIC端口上收到的CRC错误

Views:
4
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

状态信息

适用场景

  • ONTAP 9
  • FAS/AFF 系统
  • 在单个数据端口上报告CRC错误
  • 使用SFP和光缆的数据端口

问题描述

  • 事件日志报告物理和/或逻辑端口上的硬件错误。

[node-01: vifmgr: vifmgr.cluscheck.crcerrors]: Port a0b on node node-01 is reporting a high number of observed hardware errors, possibly CRC errors
[node-02: vifmgr: vifmgr.cluscheck.crcerrors]: Port e0d on node node-02 is reporting a high number of observed hardware errors, possibly CRC errors
[node-02: vifmgr: vifmgr.cluscheck.hwerrors:alert]: Port e0d on node node-02 is reporting a high number (at least 1 per 1000 packets) of observed hardware errors (CRC, length, alignment, dropped)

  • ifstat 如果ONTAP 收到错误、则输出将显示CRC错误。
  • 更换缆线/SFP后、问题描述 已解决

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.