跳转到主内容

在同一抽盒中缺少多个磁盘后、聚合出现故障

适用场景

  • DS460C
  • 多磁盘故障 / 磁盘缺失

问题描述

  • 在 DS460C 上重新拔插 IOM A 后出现多磁盘崩溃
  • 由于同一磁盘架抽屉缺少磁盘,聚合显示为失败。system node run -node node_name -command sysconfig -r 示例: 
 Aggregate aggr_n02_data01 (failed, raid_tec, partial) (block checksums) Plex /aggr_n02_data01/plex0 (offline, failed, inactive) RAID group /aggr_n02_data01/plex0/rg0 (partial, block checksums) RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks) --------- ------ ------------- ---- ---- ---- ----- -------------- -------------- tparity FAILED N/A 9324290/ - dparity 9c.13.6 9c 13 6 SA:A 0 FSAS 7200 9324290/19096145920 9342976/19134414848 parity 9a.11.6 9a 11 6 SA:B 0 FSAS 7200 9324290/19096145920 9342976/19134414848 data 9c.12.6 9c 12 6 SA:A 0 FSAS 7200 9324290/19096145920 9342976/19134414848 data 9a.10.6 9a 10 6 SA:B 0 FSAS 7200 9324290/19096145920 9342976/19134414848 data 9a.10.30 9a 10 30 SA:B 0 FSAS 7200 9324290/19096145920 9342976/19134414848 (reconstruct stalled) data 9c.13.7 9c 13 7 SA:A 0 FSAS 7200 9324290/19096145920 9342976/19134414848 data 9a.11.7 9a 11 7 SA:B 0 FSAS 7200 9324290/19096145920 9342976/19134414848 data 9c.12.7 9c 12 7 SA:A 0 FSAS 7200 9324290/19096145920 9342976/19134414848 data 9a.10.7 9a 10 7 SA:B 0 FSAS 7200 9324290/19096145920 9342976/19134414848 data FAILED N/A 9324290/ - data 9c.13.8 9c 13 8 SA:A 0 FSAS 7200 9324290/19096145920 9342976/19134414848 data 9a.11.8 9a 11 8 SA:B 0 FSAS 7200 9324290/19096145920 9342976/19134414848 data 9c.12.8 9c 12 8 SA:A 0 FSAS 7200 9324290/19096145920 9342976/19134414848 data 9a.10.8 9a 10 8 SA:B 0 FSAS 7200 9324290/19096145920 9342976/19134414848 data FAILED N/A 9324290/ - data 9c.13.9 9c 13 9 SA:A 0 FSAS 7200 9324290/19096145920 9342976/19134414848 data 9a.11.9 9a 11 9 SA:B 0 FSAS 7200 9324290/19096145920 9342976/19134414848 data 9c.12.9 9c 12 9 SA:A 0 FSAS 7200 9324290/19096145920 9342976/19134414848 data 9a.10.9 9a 10 9 SA:B 0 FSAS 7200 9324290/19096145920 9342976/19134414848 data FAILED N/A 9324290/ - data 9c.13.10 9c 13 10 SA:A 0 FSAS 7200 9324290/19096145920 9342976/19134414848 data 9a.11.10 9a 11 10 SA:B 0 FSAS 7200 9324290/19096145920 9342976/19134414848 data 9c.12.10 9c 12 10 SA:A 0 FSAS 7200 9324290/19096145920 9342976/19134414848 data 9a.10.10 9a 10 10 SA:B 0 FSAS 7200 9324290/19096145920 9342976/19134414848 Raid group is missing 4 disks. 
  • 由于磁盘架中通过通道 B 使用了现有的问题描述,因此在重新拔插期间,无法通过路径访问单个抽屉中的磁盘
Drawers Control Module:
Element Status                      Status Bytes  Status Descriptions
1 [IOM12 A]    : OK                01,00,01,00   REPORT
2 [IOM12 A]    : OK                01,00,01,00   REPORT
3 [IOM12 A]    : OK                01,00,01,00   REPORT
4 [IOM12 A]    : OK                01,00,01,00   REPORT
5 [IOM12 A]    : OK                01,00,01,00   REPORT
6 [IOM12 B]    : CRITICAL          02,40,00,00   FAIL
7 [IOM12 B]    : OK                01,00,01,00   REPORT
8 [IOM12 B]    : OK                01,00,01,00   REPORT
9 [IOM12 B]    : OK                01,00,01,00   REPORT
10 [IOM12 B]    : OK                01,00,01,00   REPORT
 
  • 重新插入 IOM A 后,聚合仍会出现故障
::> storage aggregate show -fields state
aggregate       state
--------------- ------
aggr_n01_data01 online
aggr_n01_data02 online
aggr_n01_data03 online
aggr_n01_root   online
aggr_n02_data01 failed
 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.