发生多磁盘崩溃后,聚合脱机
适用场景
- ONTAP 9
- FAS/AFA系统
问题描述
- 由于聚合脱机而导致数据中断。
- 节点会在多磁盘崩溃后重新启动:
[Node01: config_thread: raid.vol.failed:notice]: Aggregate aggr1: Failed due to multi-disk error.
[Node01: config_thread: sk.panic:alert]: Panic String: aggr aggr1: raid volfsm, fatal multi-disk error.. Raid type - raid_dp Group name plex0/rg0 state DEGRADEDRECONS. 1 disk failed in the group. Disk 0n.2P2 Shelf 0 Bay 2 [NETAPP X1234 NA51] S/N [S6XXXXXXXXXXXXXXX02] UID [66304C30:___:00000000] error: disk failed. in SK process config_thread on release 9.8P1 (C)