跳转到主内容

Active Directory 上的第三方防火墙正在阻止端口 389 和 445

Views:
37
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
nas<a>2008955505</a><a>防火墙 AD</a><a>操作超时</a>
Last Updated:

适用场景

  • ONTAP 9
  • SMB/CIFS

问题描述

  • 在尝试访问 Active Directory ( AD )时, AD 会在尝试连接到端口 389 或 445 时关闭连接。
  • 可以通过 tcpdump 查看此信息:
clipboard_e1f3334ad1e0cce0a176f81190292165a.png
 
  • 我们还可以在 secd/ems 日志中看到此信息:

[Node1: secd: secd.conn.auth.failure:debug]: Vserver (svm1) could not make a connection over the network to server (ip 10.1.2.123, port 445). Error: Operation timed out ().
[Node1: secd: secd.lsa.noServers:debug]: None of the LSA servers configured for Vserver (svm1) are currently accessible via the network.

[Cluster01-01: secd: secd.cifsAuth.problem:error]: vserver (SVM1) General CIFS authentication problem. Error: User authentication procedure failed CIFS SMB2 Share mapping - Client Ip = 10.1.1.2
[ 0 ms] Login attempt by domain user 'NetApp\bob' using NTLMv2 style security
[ 0] Using a cached connection to DC1.NetApp.com
[ 26] Authentication failed with DC DC1. Not retriable. (Status: 0xc0000064)
[ 27] Unable to find the NetBIOS domain name for Active Directory '.' **
[ 27] FAILURE: CIFS authentication failed
[ 2125] TCP connection to ip 10.10.10.10, port 389 via interface 10.10.10.2 failed: Operation timed out.
[ 4159] Unable to connect to LDAP (Active Directory) service on DC2.NetApp.com (Error: Can't contact LDAP server
 
 
  [  8007] TCP connection to ip 172.24.100.5, port 445 via interface 10.101.7.41 failed: Operation timed out.
  [  8007] Could not open a socket to 'dc002cd.netapp.cn'
  [  8007] Unable to connect to NetLogon service on dc002cd.netapp.cn (Error: RESULT_ERROR_SPINCLIENT_UNABLE_TO_RESOLVE_SERVER)
**[  8007] FAILURE: Unable to make a connection (NetLogon:netapp.CN), result: 6942
  [  8007] CIFS authentication failed
  [  8007] Retry requested, but the retry window (7000 ms) has expired; giving up.

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.