由于已中止规范化启动程序名称任务、无法完成升级到ONTAP 9.11.1或更高版本

Views:
1
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
san<a>2009345878</a>
Last Updated:

适用场景

  • 9.11.1或更高版本
  • 自动化无中断升级(ANDU)

问题描述

  • 在启动程序包含大写字符的集群上升级到ONTAP 9.11.1时、升级可能会失败、并显示有关无法标准化启动程序名称的错误。   not logged in  使用命令行界面命令时、这些启动程序可能显示为: igroup show -v 

 

  • 在使用较新的ONTAP版本重新启动节点后、由于升级未完成、ANDU将暂停。
 
::>cluster image show-upgrade-progress
Summary:
Upgrade failed to complete.
failed Error: Upgrade of node "ntap-clus01-node01-hapairA-firstnode" failed to complete.
Action: Use the (privilege: advanced)command "system node upgrade-revert show -node <nodename>" to check the upgrade status.
 
  • 运行 ::>system node upgrade-revert show时,任务显示“已中止”:
Node: ntap-clus01-node01-hapairA-firstnode Status: aborted Status Message: The upgrade aborted in the "post-apps" phase on task "Normalize Initiator Names Upgrade Revert Task". Contact support personnel for the upgrade repair procedure. Vers Phase Status Upgrade Phase Status Message ---- ---------- -------- ------------------------------------------------------ 1400 pre-root applied No upgrade is required for this phase. 1400 pre-apps applied Upgrade successful. 1400 post-apps applied Upgrade successful. 1800 pre-root applied No upgrade is required for this phase. 1800 pre-apps applied No upgrade is required for this phase. 1800 post-apps aborted A duplicate initiator was found after normalizing initiator names to lower case characters. Verify the configuration of the initiator using the "lun mapping show -initiator 20:00:00:25:B5:15:1B:01|20:00:00:25:b5:15:1b:01" and "igroup show -initiator 20:00:00:25:B5:15:1B:01|20:00:00:25:b5:15:1b:01" commands. The same igroup or LUN map must not contain the same initiator more than once regardless of character case. Different Vservers refering to the same initiator must use the same character case. Resolve any conflicts and then resume the upgrade. 6 entries were displayed. You may also see the following Status Message for the aborted task:
  • 对于已中止的任务、您可能还会看到以下状态消息:
Duplicate initiators are mapped to the same LUN. Do not try to fix this problem. Using either the 'lun mapping delete' command or the 'lun igroup remove' command could lead to an outage. Contact technical support for assistance.

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.