跳转到主内容

SwitchPsuFanNotOperational_Alert—AutoSupport 消息

Views:
1
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches
Specialty:
hw
Last Updated:

适用场景

  • ONTAP 9
    • MetroCluster 光纤交换机
    • 集群网络交换
    • NetApp集群交换机
    • Broadcom交换机
    • Cisco 交换机
  • callhome.hm.alert.Major
    • 致电主页查看运行状况监控器进程cshm:SwitchPowerFail警报

事件摘要

如果集群交换机上的风扇有电源、则会发送SwitchPsuFanNotOperational_Alert、但当风扇的电源指示其正在运行时、风扇状态本身指示风扇未运行。 

验证

AutoSupport 消息

HA Group Notification from Node Name (Health Monitor process cshm: SwitchPsuFanNotOperational_Alert[Switch Name(Serial Numer)/PowerSupply-1 Fan-1]) ALERT

EMS日志

event log show -severity * -message-name callhome*

[node1: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process cshm: SwitchPsuFanNotOperational_Alert[Switch_Name(########)/PowerSupply-2 Fan-1].

命令行

system health alert show -node <node name> -monitor cluster-switch -alert-id SwitchPsuFanNotOperational

            Node: Node01
          Monitor: cluster-switch
       Class of Alert: SwitchPsuNotOperational_Alert
     Severity of Alert: Major
       Probable Cause: Out_of_service
Probable Cause Description: "Fan Module-3" on switch "Switch Name(Switch Name)" is not functioning properly.
      Possible Effect: Cooling of switch "Switch Name(Serial Number)" might be degraded.
     Corrective Actions: 1) Use the switch CLI to verify that the fan is functioning at the expected speed.                      2) Replace the fan, if it is not operational. 

解决方法

  1. 验证是否已安装电源。
  2. 验证电源是否已通电。
  3. 如果确定电源存在故障、请予以更换。

 

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.
Scan to view the article on your device