适用场景

Brocade 交换机上的端口

问题描述

  • 交换机端口状态显示为 No_light 输出下方switchshow

Index Port Address Media Speed  State    Proto
==============================================
 ----- Truncated -----
   5   5   010500   id     4G   No_Light    FC  

  • porterrshow输出显示出现链路故障、丢失SIG错误

/fabos/cliexec/porterrshow :
frames     enc   crc    crc    too   too    bad    enc   disc   link   loss   loss   frjt   fbsy   c3timeout    pcs    uncor
tx     rx    in    err    g_eof  shrt   long   eof   out   c3    fail   sync   sig            tx    rx    err    err
130:  403   471     0     0    0     0     0    0     0     0   334    0    5.4k  0     0     0    0     0     0

  • Portshow 受影响端口的状态报告:offline

portshow 5
portDisableReason: None
portCFlags: 0x0
portFlags: 0x21    PRESENT U_PORT DISABLED
LocalSwcFlags: 0x0
portType:  26.0
portState: 2   Offline  
Protocol: FC
portPhys:  4   No_Light    portScn:   2   Offline   
port generation number:   748
state transition count:   11    

  • 网络结构日志显示该端口多次发生转接

Switch 0; Thu Jun  1 19:17:40 2023 IST (GMT+5:30)
19:17:40.873933 SCN Port Offline;rsn=0x2,g=0xf1e       A2,P0  A2,P0  130  NA
19:17:40.873942 *Removing all nodes from port        A2,P0  A2,P0  130  NA
19:22:14.346217 SCN LR_PORT(0);g=0xf1e            A2,P0  A2,P0  130  NA
19:22:14.396548 SCN Port Online; g=0xf1e,isolated=0     A2,P0  A2,P1  130  NA
19:22:14.396643 Port Elp engaged               A2,P1  A2,P0  130  NA
19:22:14.396657 *Removing all nodes from port        A2,P0  A2,P0  130  NA
19:22:14.397110 SCN Port F_PORT               A2,P1  A2,P0  130  NA
19:22:14.444090 SCN Port Offline;rsn=0x2,g=0xf20       A2,P0  A2,P0  130  NA
19:22:14.444095 *Removing all nodes from port        A2,P0  A2,P0  130  NA
19:22:19.256279 SCN LR_PORT(0);g=0xf20            A2,P0  A2,P0  130  NA
19:22:30.799147 SCN LR_PORT(0);g=0xf20            A2,P0  A2,P0  130  NA
19:22:30.899258 SCN Port Online; g=0xf20,isolated=0     A2,P0  A2,P1  130  NA
19:22:30.899357 Port Elp engaged               A2,P1  A2,P0  130  NA
19:22:30.899371 *Removing all nodes from port        A2,P0  A2,P0  130  NA
19:22:30.900041 SCN Port F_PORT               A2,P1  A2,P0  130  NA   

  • sfpshow 报告Rx值过低

Slot  5/Port 21:
=============
Identifier:  3    SFP
Connector:   7    LC
Transceiver: 6804404000000000 8,16,32_Gbps M5 sw Short_dist
[...]
Vendor Name: BROCADE
Vendor OUI:  00:05:1e
Vendor PN:   57-1000333-01
Vendor Rev:  A
[...]
Temperature: 59      Centigrade
Current:     7.640   mAmps
Voltage:     3327.1  mVolts
RX Power:    -25.1   dBm (3.1  uW)
TX Power:    -1.3    dBm (743.9 uW)

  • 在错误转储日志中观察到端口的传输字(ITW)无效错误

2022/11/27-00:23:05, [MAPS-1003], 84606, SLOT 2 | FID 128, WARNING, NTTC_X6_108_FAB2, slot10 port38, F-Port 10/38, Condition=ALL_TARGET_PORTS(ITW/min>11), Current Value:[ITW, 237558518 ITWs], RuleName=defALL_TARGET_PORTSITW_11, Dashboard Category=Port Health.
2022/11/27-00:24:05, [MAPS-1003], 84607, SLOT 2 | FID 128, WARNING, NTTC_X6_108_FAB2, slot10 port38, F-Port 10/38, Condition=ALL_TARGET_PORTS(ITW/min>11), Current Value:[ITW, 222669296 ITWs], RuleName=defALL_TARGET_PORTSITW_11, Dashboard Category=Port Health

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.