Brocade交换机端口脱机且处于"无光"状态且Tx功率低
适用场景
Brocade交换机
问题描述
- 交换机端口状态
No_light
在switchshow
输出下方显示为:
Index Port Address Media Speed State Proto
==============================================
----- Truncated -----
5 5 010500 id 4G No_Light FC
Portshow
受影响的端口报告offline
状态:
portshow 5
portDisableReason: None
portCFlags: 0x0
portFlags: 0x21 PRESENT U_PORT DISABLED
LocalSwcFlags: 0x0
portType: 26.0
portState: 2 Offline
Protocol: FC
portPhys: 4 No_Light portScn: 2 Offline
port generation number: 748
state transition count: 11
sfpshow
报告Tx值过低
Slot 5/Port 21:
=============
Identifier: 3 SFP
Connector: 7 LC
Transceiver: 6804404000000000 8,16,32_Gbps M5 sw Short_dist
[...]
Vendor Name: BROCADE
Vendor OUI: 00:05:1e
Vendor PN: 57-1000333-01
Vendor Rev: A
[...]
Temperature: 59 Centigrade
Current: 7.640 mAmps
Voltage: 3327.1 mVolts
RX Power: -25.1 dBm (744.6 uW)
TX Power: -1.3 dBm (4.9 uW)