跳转到主内容

E 系列阵列无法添加到 SANtricity SMI-S Provider

Views:
28
Visibility:
Public
Votes:
0
Category:
e-series-santricity-os-controller-software
Specialty:
esg
Last Updated:

适用于

  • SANtolicy OS 任何版本
  • SANtricity SMI-S Provider 任何版本

问题

 

  • E 系列阵列无法添加到 SANtricity SMI-S Provider
  • SMI-S SBMA 日志中也存在类似的条目
04/14/2020 11:14:50 4508  [INFO   ] (INTERNAL) - Connection::discoverControllers() - Connecting to controller with IP of 10.18.48.65
04/14/2020 11:15:11 4508  [DEBUG  ] (INTERNAL) - Connection::discoverControllers() - RC is 18 - retry 0
04/14/2020 11:15:11 4508  [ERROR  ] (INTERNAL) - Connection::discoverControllers() - Error connecting to host. RPC error code = 18
04/14/2020 11:15:11 4508  [VERBOSE] (INTERNAL) - Connection::discoverControllers() Leaving
04/14/2020 11:15:11 4508  [ERROR  ] (INTERNAL) - SYMbolAdapter::addArrayToRepository() - Failed to get discoveryResponse for IP address: 10.18.48.65
04/14/2020 11:15:11 4508  [VERBOSE] (INTERNAL) - SYMbolAdapter::addArrayToRepository() Leaving
  • 控制器管理 IP 的端口 2463 上的 Telnet 没有响应

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.