跳转到主内容

ONTAP Select 节点意外重启

Views:
59
Visibility:
Public
Votes:
0
Category:
ontap-select
Specialty:
ontapselect
Last Updated:

适用于

  • NetApp ONTAP Select
  • VMware ESXi

说明

  • ONTAP Select (OTS) 节点/VM 意外重新启动并自动返回在线。
  • 查看 NetApp AutoSupport (ASUP) 事件日志后,多个磁盘丢失,节点失败,PLEX 脱机。
  • 日志可能显示:
  • [TEST-ONTAP-1-2: dmgr_thread: raid.disk.missing:info]: Disk 0d.36 S/N [00000000vXHOaJhGtfcm] UID [00000000vXHOaJhGtfcm] is missing from the system [?] [TEST-ONTAP-1-2: dmgr_thread: raid.disk.missing:info]: Disk 0d.40 S/N [0VpF0-csxVspEkBpP/VW] UID [0VpF0-csxVspEkBpP/VW] is missing from the system [?] [TEST-ONTAP-1-2: dmgr_thread: raid.disk.missing:info]: Disk 0d.42 S/N [00000000lDhW37cEPycq] UID [00000000lDhW37cEPycq] is missing from the system [?] [TEST-ONTAP-1-2: config_thread: raid.config.filesystem.disk.missing:info]: File system Disk /aggr0_TEST_ONTAP_1_2_0/plex6/rg0/0d.13 S/N [0VpF0-csRXEBLurW1fN3] UID [0VpF0-csRXEBLurW1fN3] is missing. [?] [TEST-ONTAP-1-2: dmgr_thread: raid.disk.missing:info]: Disk 0d.38 S/N [0VpF0-csiAo3Li1jTxw6] UID [0VpF0-csiAo3Li1jTxw6] is missing from the system [?] [TEST-ONTAP-1-2: config_thread: raid.config.filesystem.disk.missing:info]: File system Disk /aggr2/plex5/rg0/0d.34 S/N [0VpF0-csScX-sMoWmBo5] UID [0VpF0-csScX-sMoWmBo5] is missing. [?] [TEST-ONTAP-1-2: config_thread: raid.config.filesystem.disk.missing:info]: File system Disk /aggr2/plex5/rg0/0d.17 S/N [0VpF0-csxDwZA-4opUVg] UID [0VpF0-csxDwZA-4opUVg] is missing. [?] [TEST-ONTAP-1-2: config_thread: raid.config.filesystem.disk.missing:info]: File system Disk /aggr2/plex5/rg0/0d.30 S/N [00000000PC6QgHbIossk] UID [00000000PC6QgHbIossk] is missing. [?] [TEST-ONTAP-1-2: cf_takeover: cf.rsrc.transitTime:debug]: Top Takeover transit times disk_assignment=98, lock manager=146, ffo_bdata_cleanup=184, registry_prerc=202, wafl_replay=204 {op_replay_0=147, validate_bkts=23, enable_log=19, prep_log _0=12, init=1, sync_log_0=1, mark_replaying=0, catalog_init=0, replay_log_missing=0, nvfail=0}, registry_postrc_phase1=270 {set_start1=0, start_stop=56 {timed=0, tftpd=0, snmp=0}, set_start2=0, snmpv3_user_init=0, reg_per_check=108, snmp_res_traphost=0}, wafl=352 {paggrs_to_done=212, pvvols_to_done=114, prvol_to_done=24, snapmirror_cg_sync_=0, verify_names=0}, wafl_make_mounted=390 {wait_cp=385, pvols_mnt_end=2, prvol_pre_mnt_end=1, flush_raid_dirty_vo=1, destroy_vvol=0, pvols_pre_mnt_end=0, finish=0}, aure_vnvram_handshake=3047, xl=5032. [?] [TEST-ONTAP-1-2: config_failed_disk: callhome.disks.missing:error]: Call home for MULTIPLE DISKS MISSING

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.