ONTAP Select 节点意外重启
适用于
- NetApp ONTAP Select
- VMware ESXi
说明
- ONTAP Select (OTS) 节点/VM 意外重新启动并自动返回在线。
- 查看 NetApp AutoSupport (ASUP) 事件日志后,多个磁盘丢失,节点失败,PLEX 脱机。
- 日志可能显示:
dmgr_thread: raid.disk.missing:info]: Disk 0x.x S/N [..] UID [..] is missing from the system config_thread: raid.config.filesystem.disk.missing:info: File system Disk /aggr0_/plex/rg0/0x.1x S/N [..] UID [..] is missing. config_failed_disk: callhome.disks.missing:error]: Call home for MULTIPLE DISKS MISSING mlm.array.lun.removed: Array LUN '0x.x' is no longer being presented fmmb_disk_io_replyFailed: no valid path to disk 0x.x