跳转到主内容

收到指示文件系统磁盘故障的AutoSupport通知

Views:
1
Visibility:
Public
Votes:
0
Category:
ontap-select
Specialty:
core
Last Updated:

适用场景

  • ONTAP Select
  • VMware

问题描述

  • 收到指示文件系统磁盘故障的AutoSupport通知:

System Notification from node (FILESYSTEM DISK FAILED Shelf -, Bay -, Model [PHA-DISK], S/N [0-2svZ-EV8xxxxxx]) ERROR

  • 磁盘在System Manager中显示为"已损坏"
  • 虚拟服务器的物理磁盘运行正常
  • 日志中的错误消息:

ASUP EMS-LOG-FILE.GZ:
[?]  Sat Apr 05 07:24:17 +0900 [nodename: pha_main000: scsi.cmd.checkCondition:error]: Disk device 0b.9L0: Check Condition: CDB 0x88:000000039ba31d00:00000008: Sense Data SCSI:medium error - Unrecovered read error (0x3 - 0x11 0x0 0x0)(2). Disk 0b.9 S/N [0-2svZ-xxxxxxxx] UID [0-2svZ-xxxxxxxx] Target Address [Scsi bus=3, target=1, lun=0]
[?]  Sat Apr 05 07:24:17 +0900 [nodename: pha_main000: disk.ioMediumError:notice]: Medium error on disk 0b.9: op 0x88:000000039ba31d00:00000008 sector 0 SCSI:medium error - Unrecovered read error   (3 11 0 0) (2) Disk 0b.9 S/N [0-2svZ-xxxxxxxx] UID [0-2svZ-xxxxxxxx] Target Address [Scsi bus=3, target=1, lun=0]
[?]  Sat Apr 05 07:24:17 +0900 [nodename: pha_main000: disk.senseInfoNotValid:error]: Disk 0b.9: sense data information field is not valid.

ASUP SYSCONFIG-R:
RAID Disk Device HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)   Phys (MB/blks)
--------- ------ ------------- ---- ---- ---- ----- --------------   --------------
data    0b.7 0b   -   -   SA:A   - VMDISK   N/A 16515064/33822852992 16777215/34359738360
data    0b.3 0b   -   -   SA:A   - VMDISK   N/A 16515064/33822852992 16777215/34359738360
data    0b.5 0b   -   -   SA:A   - VMDISK   N/A 16515064/33822852992 16777215/34359738360
data  FAILED  N/A             16515064/ - 
.....

Raid group is missing 1 disk.

Broken disks
RAID Disk Device HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)   Phys (MB/blks)
--------- ------ ------------- ---- ---- ---- ----- --------------   --------------
failed   0b.9 0b   -   -   SA:A   - VMDISK   N/A 16777209/34359725568 16777215/34359738360 

  • 在出现磁盘错误期间生成核心文件:

Panic Message: aggr aggr1_nodename: raid volfsm, fatal disk error in RAID group with no parity disk..

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.