收到指示文件系统磁盘故障的AutoSupport通知
适用场景
- ONTAP Select
 - VMware
 
问题描述
- 收到指示文件系统磁盘故障的AutoSupport通知:
 
System Notification from node (FILESYSTEM DISK FAILED Shelf -, Bay -, Model [PHA-DISK], S/N [0-2svZ-EV8xxxxxx]) ERROR
- 磁盘在System Manager中显示为"已损坏"
 - 虚拟服务器的物理磁盘运行正常
 - 日志中的错误消息:
 
ASUP EMS-LOG-FILE.GZ:
 [?]  Sat Apr 05 07:24:17 +0900 [nodename: pha_main000: scsi.cmd.checkCondition:error]: Disk device 0b.9L0: Check Condition: CDB 0x88:000000039ba31d00:00000008: Sense Data SCSI:medium error - Unrecovered read error (0x3 - 0x11 0x0 0x0)(2). Disk 0b.9 S/N [0-2svZ-xxxxxxxx] UID [0-2svZ-xxxxxxxx] Target Address [Scsi bus=3, target=1, lun=0]
 [?]  Sat Apr 05 07:24:17 +0900 [nodename: pha_main000: disk.ioMediumError:notice]: Medium error on disk 0b.9: op 0x88:000000039ba31d00:00000008 sector 0 SCSI:medium error - Unrecovered read error   (3 11 0 0) (2) Disk 0b.9 S/N [0-2svZ-xxxxxxxx] UID [0-2svZ-xxxxxxxx] Target Address [Scsi bus=3, target=1, lun=0]
 [?]  Sat Apr 05 07:24:17 +0900 [nodename: pha_main000: disk.senseInfoNotValid:error]: Disk 0b.9: sense data information field is not valid.
ASUP SYSCONFIG-R:
 RAID Disk Device HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)   Phys (MB/blks)
 --------- ------ ------------- ---- ---- ---- ----- --------------   --------------
 data    0b.7 0b   -   -   SA:A   - VMDISK   N/A 16515064/33822852992 16777215/34359738360
 data    0b.3 0b   -   -   SA:A   - VMDISK   N/A 16515064/33822852992 16777215/34359738360
 data    0b.5 0b   -   -   SA:A   - VMDISK   N/A 16515064/33822852992 16777215/34359738360
 data  FAILED  N/A             16515064/ - 
 .....
Raid group is missing 1 disk.
Broken disks
 RAID Disk Device HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)   Phys (MB/blks)
 --------- ------ ------------- ---- ---- ---- ----- --------------   --------------
 failed   0b.9 0b   -   -   SA:A   - VMDISK   N/A 16777209/34359725568 16777215/34359738360 
- 在出现磁盘错误期间生成核心文件:
 
Panic Message: aggr aggr1_nodename: raid volfsm, fatal disk error in RAID group with no parity disk..