跳转到主内容

X1151A 端口未与光缆联机

Views:
6
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster
Last Updated:

适用于

  • X1151A 双 100G 以太网控制器 IONIC 卡
  • X65405 QSFP 收发器
  • X66200-<n> MPO 光缆

问题描述

  • 使用光缆时,e3a/e3b 端口需要 15-20 分钟才能上线:

Wed Dec 13 11:56:02 +0800 [Node-02: nblade1: netif.linkInfo:info]: Ethernet adapter e3a: Link Resetting.
Wed Dec 13 11:56:05 +0800 [Node-02: nblade1: netif.linkInfo:info]: Ethernet adapter e3b: Link Resetting.
                    
Wed Dec 13 12:14:32 +0800 [Node-02: vifmgr: vifmgr.portup:notice]: A link up event was received on node Node-02, port e3b.
Wed Dec 13 12:14:32 +0800 [Node-02: vifmgr: vifmgr.portup:notice]: A link up event was received on node Node-02, port e3a.

  • 在某些情况下,这可能表现为"拍打"端口问题,而不是端口不出现。
  • 如果遇到此问题,自动 ONTAP 升级可能会暂停,出现以下错误:

[Node-01: upgrademgr: upgrademgr.update.pausedErr:error]: The automated update of the cluster has been paused due to the following reason: Error: {Update timeout occured in State[Giveback]-- Tasks Pending in nodes  Task Name: do-giveback-job}, Action: {Ensure that nodes are healthy and try resuming the update operation after some time}
Wed Dec 13 12:10:51 +0800 [Node-01: notifyd: callhome.andu.pausederr:alert]: params: {'subject': 'AUTOMATED NDU PAUSED ON NODE: MUM', 'epoch': '6ddXXX0-bXX3-4XXf-b7c1-aXXXXXXXXXX67'}

  • 手动将交换机端口速度设置为 100G 并不能解决此问题。
  • 从交换机 CLI,端口可能会在 show interface brief 命令的输出中因抖动而报告 errdisable
  • 使用铜缆时,e3a/e3b 端口立即上线。

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.