更换主板后、切回模拟失败
适用场景
- 双节点延伸型MetroCluster
- ONTAP 9
- 更换主板后出现错误
问题描述
- 命令"vserver switchback -simulate true"失败、因为一个或多个MetroCluster 配置已降级
示例:
Failed to validate the node and cluster components before the switchback operation. <cluster> (non-overridable veto): Internal error. The Vserver configuration state was set to "degraded" because configuration replication failed. Reason: MetroCluster Vserver stream operation failed. Run "metrocluster vserver show -configuration-state degraded -fields corrective-action" to view detailed recovery information.
- MetroCluster vserver show的输出报告了一个或多个SVM上缺少许可证的错误
示例:Unrecoverable error during configuration replication, requires manual intervention. Error: You do not have a valid license for "FCP". Reason: Package "FCP" is not licensed in the cluster.