StorageFCAdapterFault_Alert—解决方案指南
适用场景
- ONTAP 9
- MetroCluster光纤通道
- StorageFCAdapterFault_Alert
问题描述
如果检测到启动程序链路关闭、则会在FC MetroCluster系统上触发StorageFCAdapterFault_Alerts。此警报可能有多种原因。
- 自动通报警报:
[mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process nchm: StorageFCAdapterFault_Alert [100000109bxxxxxx].
- MetroCluster_Node子系统运行状况报告已降级:
cluster::>system health subsystem show
 Subsystem      Health
 ----------------- ------------------
 SAS-connect     ok
 Environment     ok
 Memory       ok
 Service-Processor ok
 Switch-Health    ok
 CIFS-NDO      ok
 Motherboard     ok
 IO         ok
 MetroCluster    ok
 MetroCluster_Node degraded
 FHM-Switch     ok
 FHM-Bridge     ok
 SAS-connect_Cluster
           ok
 13 entries were displayed.
- 运行状况警报报告适配器出现故障:
cluster::>system health alert show
                Node: node-01
            Resource: 4d
            Severity: Major
     Indication Time: Sat Aug 15 13:05:58 2020
            Suppress: false
         Acknowledge: false
      Probable Cause: FC initiator adapter 4d is at fault.
     Possible Effect: Resiliency of backend storage is compromised.
  Corrective Actions: 1. Ensure that the FC initiator link has not been tampered with.
                      2. Verify the operational status of the FC initiator
                      adapter by using the command "system node run -node
                      local -command storage show adapter".
- 事件日志报告:
::>event log show
[slifc_intrd: fci.link.break:error]: Link break detected on Fibre Channel adapter 4d.
 [slifc_timeout_3: fci.link.error:error]: Could not recover link on Fibre Channel adapter 4d after 30 seconds. Taking the adapter offline.
 [nchmd: hm.alert.raised:alert]: Alert Id = StorageFCAdapterFault_Alert , Alerting Resource = 100000109bxxxxxx raised by monitor node-connect