跳转到主内容

StorageFCAdapterFault_Alert—解决方案指南

Views:
128
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
MetroCluster
Last Updated:

适用场景

  • ONTAP 9
  • MetroCluster光纤通道
  • StorageFCAdapterFault_Alert

问题描述

如果检测到启动程序链路关闭、则会在FC MetroCluster系统上触发StorageFCAdapterFault_Alerts。此警报可能有多种原因。

  • 自动通报警报:

[mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process nchm: StorageFCAdapterFault_Alert [100000109bxxxxxx].

  • MetroCluster_Node子系统运行状况报告已降级:

cluster::>system health subsystem show
Subsystem      Health
----------------- ------------------
SAS-connect     ok
Environment     ok
Memory       ok
Service-Processor ok
Switch-Health    ok
CIFS-NDO      ok
Motherboard     ok
IO         ok
MetroCluster    ok
MetroCluster_Node degraded
FHM-Switch     ok
FHM-Bridge     ok
SAS-connect_Cluster
          ok
13 entries were displayed.

  • 运行状况警报报告适配器出现故障:

cluster::>system health alert show
               Node: node-01
           Resource: 4d
           Severity: Major
    Indication Time: Sat Aug 15 13:05:58 2020
           Suppress: false
        Acknowledge: false
     Probable Cause: FC initiator adapter 4d is at fault.
    Possible Effect: Resiliency of backend storage is compromised.
 Corrective Actions: 1. Ensure that the FC initiator link has not been tampered with.
                     2. Verify the operational status of the FC initiator
                     adapter by using the command "system node run -node
                     local -command storage show adapter".

  • 事件日志报告:

::>event log show

[slifc_intrd: fci.link.break:error]: Link break detected on Fibre Channel adapter 4d.
[slifc_timeout_3: fci.link.error:error]: Could not recover link on Fibre Channel adapter 4d after 30 seconds. Taking the adapter offline.
[nchmd: hm.alert.raised:alert]: Alert Id = StorageFCAdapterFault_Alert , Alerting Resource = 100000109bxxxxxx raised by monitor node-connect

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.