运行状况监控进程nchm:StorageFCAdapterFault_Alert - AutoSupport 消息
适用场景
- MetroCluster FC
- ONTAP 9
StorageFCAdapterFault_Alert
事件摘要
当MetroCluster 运行状况监控器检测到FC启动程序端口已关闭时、ONTAP 光纤通道系统会生成StorageFCAdapterFault警报。验证
- 检查的输出
system health alert show
以查看当前报告错误:
Cluster01::>system health alert show
Node: NodeA-01
Resource: 2b
Severity: Major
Indication Time: Thu Aug 05 00:06:31
Suppress: false
Acknowledge: false
Probable Cause: FC initiator adapter 2b is at fault.
Possible Effect: Resiliency of backend storage is compromised.
Corrective Actions: 1. Ensure that the FC initiator link has not been tampered with.
2. Verify the operational status of the FC initiator adapter by using the command
"system node run -node local -command storage show adapter".
- 检查报告适配器的当前状态:
system node run -node <node_name> -command storage show adapter <adapter>
Cluster01::>system node run -node NodeA-01 -command storage show adapter 2b
Slot: 2b
Description: Fibre Channel Host Adapter 2b (QLogic 2532 rev. 2)
Firmware Rev: 5.4.130
FC Node Name: 2:000:0024ff:
FC Port Name: 2:100:0024ff:
FC Packet Size: 2048
Link Data Rate: 8 Gbit
SRAM Parity: Yes
External GBIC: No
State: Enabled
In Use: Yes
Redundant: Yes
- 检查适配器连接到的交换机端口:ayatem node run -node <node_name> -command Sysconfig -v <adapter number>
Cluster01::>system node run -node NodeA-01 - command sysconfig -v 2
slot 2: FC Host Adapter 2b (QLogic 2532 rev. 2, N-port, <UP>)
Board name: QLE2564
Serial Number: RFD1404U12345
Firmware rev: 5.4.130
Preload Rev: 2.6.0
Host Port Id: 0x60600
FC Node Name: 2:000:0024ff:
FC Port Name: 2:100:0024ff:
SFP Vendor: FINISAR CORP.
SFP Part Number: FTLF1234P3BCV-QL
SFP Serial Number: PQH123456
SFP Capabilities: 2, 4 or 8 Gbit
Link Data Rate: 8 Gbit
Switch Port: Switch_A1:6
突出显示的部分指示此适配器连接到的交换机名称和端口:
- 交换机名称:switch_A1
- 交换机端口:6
解决方法
确定并更正报告FC端口和已标识交换机端口之间的任何连接问题描述。
追加信息
附加信息 _text