跳转到主内容

运行状况监控进程nchm:StorageFCAdapterFault_Alert - AutoSupport 消息

Views:
8
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster
Last Updated:

适用场景

  • MetroCluster FC
  • ONTAP 9
  • StorageFCAdapterFault_Alert

事件摘要

当MetroCluster 运行状况监控器检测到FC启动程序端口已关闭时、ONTAP 光纤通道系统会生成StorageFCAdapterFault警报。

验证

  • 检查的输出 system health alert show 以查看当前报告错误:

Cluster01::>system health alert show
               Node: NodeA-01
           Resource: 2b
           Severity: Major
    Indication Time: Thu Aug 05 00:06:31
           Suppress: false
        Acknowledge: false
     Probable Cause: FC initiator adapter 2b is at fault.
    Possible Effect: Resiliency of backend storage is compromised.
 Corrective Actions: 1. Ensure that the FC initiator link has not been tampered with.
                2. Verify the operational status of the FC initiator adapter by using the command  
                        "system node run -node local -command storage show adapter".

 

  • 检查报告适配器的当前状态: system node run -node <node_name> -command storage show adapter <adapter>

Cluster01::>system node run -node NodeA-01 -command storage show adapter 2b

Slot:            2b
Description:     Fibre Channel Host Adapter 2b (QLogic 2532 rev. 2)
Firmware Rev:    5.4.130
FC Node Name:    2:000:0024ff:
FC Port Name:    2:100:0024ff:
FC Packet Size:  2048
Link Data Rate:  8 Gbit
SRAM Parity:     Yes
External GBIC:   No
State:           Enabled
In Use:          Yes
Redundant:       Yes

 

  • 检查适配器连接到的交换机端口:ayatem node run -node <node_name> -command Sysconfig -v <adapter number>

Cluster01::>system node run -node NodeA-01 - command sysconfig -v 2

        slot 2: FC Host Adapter 2b (QLogic 2532 rev. 2, N-port, <UP>)
                Board name:        QLE2564
                Serial Number:     RFD1404U12345
                Firmware rev:      5.4.130
                Preload Rev:       2.6.0
                Host Port Id:      0x60600
                FC Node Name:      2:000:0024ff:
                FC Port Name:      2:100:0024ff:
                SFP Vendor:        FINISAR CORP.
                SFP Part Number:   FTLF1234P3BCV-QL
                SFP Serial Number: PQH123456
                SFP Capabilities:  2, 4 or 8 Gbit
                Link Data Rate:    8 Gbit
               Switch Port:       Switch_A1:6

突出显示的部分指示此适配器连接到的交换机名称和端口:

  • 交换机名称:switch_A1
  • 交换机端口:6

解决方法

确定并更正报告FC端口和已标识交换机端口之间的任何连接问题描述。

追加信息

附加信息 _text

 

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.