MetroCluster IP 交换机上报告"DomainMismatchFromNodeToShelf_Alert"
适用于
- ONTAP 9
- MetroCluster IP
- NS224 磁盘架 - 通过交换机连接
- Cisco 9336C-FX2
问题
在 MetroCluster IP 交换机上报告了 "DomainMismatchFromNodeToShelf_Alert":
Node ClusterA-02Monitor system-connectAlert IDDomainMismatchFromNodeToShelf_AlertAlerting Resource Switch-04Subsystem SAS-connect_ClusterIndication Time Fri Jul 25 08:52:47 2025Perceived Severity MajorProbable Cause Configuration_errorDescription The storage domain between the nodes ClusterA-01, ClusterA-02 and switch Switch-04 is different from the domain between the switch and shelves 4.40, 4.50, 4.60, 4.70.Corrective Actions Connect the switch Switch-04 to both the node and the shelves with the same storage domain, following the guide applicable to your shelf.Possible Effect This issue will affect conversions to direct-attached storage.Additional Information Switch Name: Switch-04Nodes: ClusterA-01, ClusterA-02Ports: ClusterA-01:e10a, ClusterA-02:e10aConnected Shelves: 4.40, 4.50, 4.60, 4.70Nodes Connected to Switch Port Range A: Switch-03, Switch-04Nodes Connected to Switch Port Range B:Alerting Resource Name Switch name: Switch-04- 警报在初始安装或维护活动期间首次触发。
- 系统存储配置报告"四路径" HA。
- 系统当前已按照以下方式正确连接电缆: