聚合修复期间遗留的磁盘
适用场景
- 延伸型 MetroCluster
 - ONTAP 9
 
问题描述
- 在聚合修复之后从灾难站点角度查看根聚合
 
  Plex /DisasterSite_root/plex0 (online, normal, active, pool0)
    RAID group /DisasterSite_root/plex0/rg0 (degraded, block checksums)
    RAID Disk   Device      HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)   Phys (MB/blks)
     ---------   ------      ------------- ---- ---- ---- ----- --------------   --------------
     dparity     4b.125L1027   4b   50  0   FC:B   0  BSAS  7200 1695466/3472315904 1695759/3472914816 
     parity    4b.125L1028   4b   50  1   FC:B   0  BSAS  7200 1695466/3472315904 1695759/3472914816 
    data     FAILED             N/A             1695466/ -
- 恢复故障驱动器后根聚合的 Active Site 视角:
 
  Plex /DisasterSite_root/plex0 (online, normal, active, pool0)
    RAID group /DisasterSite_root/plex0/rg0 (double degraded, block checksums)
    RAID Disk   Device      HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)   Phys (MB/blks)
     ---------   ------      ------------- ---- ---- ---- ----- --------------   --------------
     dparity    FAILED             N/A             1695466/ -
     parity      FAILED             N/A             1695466/ -
    data     4b.125L1029   4b   50  2   FC:B   0  BSAS 7200 1695466/3472315904 1695759/3472914816