适用场景

  • MetroCluster IP (MCC IP)
  • ONTAP 9

问题描述

  • mcc_A-02出现故障、需要更换MB。只有MCC A-01处于联机状态并接管了 MCC A-02
  • MetroCluster强制切换可使用命令执行metrocluster switchover -forced-on-disaster true -override-vetoes true
  •  由于强制切换操作、由MCC B触发的节点MCC A-01关闭
  • 切换完成后、 集群 MCC A的数据聚合 将 状态报告为"失败、RAID-DP、过期"
  • plex0将状态显示为"脱 机、失败、非活动"
  • plex1会将状态显示为"Offline、Normal、O过时"
例如:
MCC_B-01> aggr status -r MCC_A-01_aggr1
Aggregate MCC_A-01_aggr1 (failed, raid_dp, out-of-date) (block checksums)
Plex /MCC_A-01_aggr1/plex0 (offline, failed, inactive)
 
Plex /MCC_A-01_aggr1/plex1 (offline, normal, out-of-date)
RAID group /MCC_A-01_aggr1/plex1/rg0 (normal, block checksums)
RAID Disk Device HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)   Phys (MB/blks)
 --------- ------ ------------- ---- ---- ---- ----- --------------   --------------
dparity 0a.11.1P2 0a   11  1  SA:A  1  SSD  N/A 1757716/3599803904 1757724/3599820288 
parity  0a.11.2P2 0a   11  2  SA:A  1  SSD  N/A 1757716/3599803904 1757724/3599820288 
data   0a.11.3P2 0a   11  3  SA:A  1  SSD  N/A 1757716/3599803904 1757724/3599820288 
data   0a.11.4P2 0a   11  4  SA:A  1  SSD  N/A 1757716/3599803904 1757724/3599820288 
data   0a.11.5P2 0a   11  5  SA:A  1  SSD  N/A 1757716/3599803904 1757724/3599820288 
data   0a.11.6P2 0a   11  6  SA:A  1  SSD  N/A 1757716/3599803904 1757724/3599820288 
data   0a.11.8P2 0a   11  8  SA:A  1  SSD  N/A 1757716/3599803904 1757724/3599820288 
data   0a.11.9P2 0a   11  9  SA:A  1  SSD  N/A 1757716/3599803904 1757724/3599820288 
data   0a.11.10P2 0a  11  10  SA:A  1  SSD  N/A 1757716/3599803904 1757724/3599820288 
data   0a.11.11P2 0a  11  11  SA:A  1  SSD  N/A 1757716/3599803904 1757724/3599820288 
data   0a.11.0P2 0a   11  0  SA:A  1  SSD  N/A 1757716/3599803904 1757724/3599820288 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.