跳转到主内容

磁盘冗余失败:在IOM12B磁盘架扩展后、一个节点的Sysconfig -A中未显示一个路径的磁盘架和磁盘条目

Views:
11
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw
Last Updated:

适用场景

  • FAS8300
  • IOM12B磁盘架扩展

问题描述

  • 添加外部IOM12B磁盘架后、一个节点的SAS路径0d不会显示所有磁盘架和磁盘条目。
    • 扩展磁盘架之前:
      • System Storage Configuration: Multi-Path HA
        slot 0: SAS Host Adapter 0d (Broadcom SAS3616W rev. 2, SAS, <UP>)
           Firmware rev:      12.00.00.00
           NVDATA rev:        12.03.01.03
           Base WWN:          5:00a098:00xxxxx:8c
           Temperature:       Not Available
           Phy State:         [0] Enabled, 12.0 Gb/s
                              [1] Enabled, 12.0 Gb/s
                              [2] Enabled, 12.0 Gb/s
                              [3] Enabled, 12.0 Gb/s
           Mini-SAS HD Vendor:        Amphenol
           Mini-SAS HD Part Number:   112-00437+A0
           Mini-SAS HD Type:          Passive Copper (unequalized) 2m end_1
           Mini-SAS HD Serial Number: APF214xxxxxx83
           00.0 : NETAPP   X380_WVAXE10TA07 NA01 9324.2GB 520B/sect (VCJL39JP)
           ...
           00.11: NETAPP   X380_WVAXE10TA07 NA01 9324.2GB 520B/sect (VCJL78SP)
           01.0 : NETAPP   X380_WVAXE10TA07 NA01 9324.2GB 520B/sect (VCJL32LP)
           ...
           01.11: NETAPP   X380_WVAXE10TA07 NA01 9324.2GB 520B/sect (VCJL663P)
           Shelf 0: DS212-12  Firmware rev. IOM12 A: 0300  IOM12 B: 0300
           Shelf 1: DS212-12  Firmware rev. IOM12 A: 0300  IOM12 B: 0300
    • 扩展磁盘架后、所有磁盘架和磁盘条目都将消失。SAS端口0d链路已启动:

System Storage Configuration: Mixed-Path HA
slot 0: SAS Host Adapter 0d (Broadcom SAS3616W rev. 2, SAS, <UP>)
   Firmware rev:      12.00.00.00
   NVDATA rev:        12.03.01.03
   Base WWN:          5:00a098:00xxxxx:8c
   Temperature:       Not Available
   Phy State:        [0] Enabled, 12.0 Gb/s
                     [1] Enabled, 12.0 Gb/s
                     [2] Enabled, 12.0 Gb/s
                     [3] Enabled, 12.0 Gb/s
   Mini-SAS HD Vendor:        Amphenol
   Mini-SAS HD Part Number:   112-00439+A0
   Mini-SAS HD Type:          Passive Copper (unequalized) 5m end_1
   Mini-SAS HD Serial Number: APFxxxxxx27440

  • EMS-FILE-LOG.GZ 显示:

Tue Jul 04 16:59:06 +0900 [Node-01: dsa_disc: ses.multipath.ReqError:alert]: SAS disk shelf detected without a multipath configuration.
Tue Jul 04 19:45:26 +0900 [Node-01: svc_queue_thread: callhome.dsk.redun.fault:error]: Call home for DISK REDUNDANCY FAILED

  • 重新拔插或更换电缆和受影响的IOM模块,中仅显示磁盘架2条目 SYSCONFIG-A

slot 0: SAS Host Adapter 0d (Broadcom SAS3616W rev. 2, SAS, <UP>)
   Firmware rev:      12.00.00.00
   NVDATA rev:        12.03.01.03
   Base WWN:          5:00a098:00xxxxx:8c
   Temperature:       Not Available
   Phy State:        [0] Enabled, 12.0 Gb/s
                     [1] Enabled, 12.0 Gb/s
                     [2] Enabled, 12.0 Gb/s
                     [3] Enabled, 12.0 Gb/s
   Mini-SAS HD Vendor:        Amphenol
   Mini-SAS HD Part Number:   112-00439+A0
   Mini-SAS HD Type:          Passive Copper (unequalized) 5m end_1
   Mini-SAS HD Serial Number: APFxxxxxx27440
   Shelf 2: DS212-12  Firmware rev. IOM12B A: 0100  IOM12B B: 0100

  • SAS-Expander子项目显示所有路径均正常:
    • SAS-EXPANDER-MAP 显示:
      • Expanders on channel 0a:
        Level    1: WWN 500xxxxxxxxxxxa9, ID  0, Serial Number ' SHJxxxxxxxxxx48', Product 'DS21212IOM12A   ', Rev '0300', Slot A
        Level    2: WWN 500xxxxxxxxxxx2d, ID  1, Serial Number ' SHJxxxxxxxxxx49', Product 'DS21212IOM12A   ', Rev '0300', Slot A
        Level    3: WWN 500xxxxxxxxxxxb1, ID  2, Serial Number ' SHJxxxxxxxxxx46', Product 'DS21212IOM12    ', Rev '0100', Slot A
        ...
        Expanders on channel 0d:
        Level    1: WWN 500xxxxxxxxxxxb1, ID  2, Serial Number ' SHJxxxxxxxxxx46', Product 'DS21212IOM12    ', Rev '0100', Slot B
        Level    2: WWN 500xxxxxxxxxxx35, ID  1, Serial Number ' SHJxxxxxxxxxx49', Product 'DS21212IOM12A   ', Rev '0300', Slot B
        Level    3: WWN 500xxxxxxxxxxx7d, ID  0, Serial Number ' SHJxxxxxxxxxx48', Product 'DS21212IOM12A   ', Rev '0300', Slot B

    • SAS-EXPANDER-PHY-STATE 显示所有物理状态均正常:

Expander phy state on 0d.2 (NETAPP  :DS21212IOM12     SHJxxxxxxxxxx46):
                              Pwr         Invald Disprt Loss   Phy    CRC    Phy
                          Pwr Ccl Rsv Rls DWord  Error  Sync   Reset  Error  Change SATA
PHY/BAY STATE             ON  Cnt Cnt Cnt Count  Count  Count  Prob   Cnt    Cnt    Affiliation
------- ----------------- --- --- --- --- ------ ------ ------ ------ ------ ------ ----------------
 0/P0:0 12.0 Gb/s         --- --- --- --- 0      0      0      0      0      1      ----------------
 1/P0:1 12.0 Gb/s         --- --- --- --- 0      0      0      0      0      1      ----------------
 2/P0:2 12.0 Gb/s         --- --- --- --- 0      0      0      0      0      1      ----------------
 3/P0:3 12.0 Gb/s         --- --- --- --- 0      0      0      0      0      1      ----------------
 ...
 8/P2:0 12.0 Gb/s         --- --- --- --- 0      0      0      0      0      15     ----------------
 9/P2:1 12.0 Gb/s         --- --- --- --- 0      0      0      0      0      15     ----------------
10/P2:2 12.0 Gb/s         --- --- --- --- 0      0      0      0      0      15     ----------------
11/P2:3 12.0 Gb/s         --- --- --- --- 0      0      0      0      0      15     ----------------
...

  • HA配对节点为多路径节点:

System Storage Configuration: Multi-Path HA

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.