跳转到主内容

单个磁盘的磁盘冗余失败

Views:
66
Visibility:
Public
Votes:
1
Category:
aff-series
Specialty:
hw
Last Updated:

适用于

  • ONTAP 9
  • DISK REDUNDANCY FAILED 的 Call home

问题

  • EMS 警报和 callhome
dsa_disc: callhome.dsk.redun.fault:error]: Call home for DISK REDUNDANCY FAILED
  • sysconfig -a 输出显示路径上缺少磁盘
slot 0: SAS Host Adapter 0a (PMC-Sierra PM8070 rev. C, SAS, <UP>)
    [...]
    00.20: NETAPP   X371_S1643960ATE NA54 915.4GB 520B/sect (XXXXXXXXXXXXXX)
    00.21: NETAPP   X371_S1643960ATE NA54 915.4GB 520B/sect (XXXXXXXXXXXXXX)
    00.22: NETAPP   X371_S1643960ATE NA54 915.4GB 520B/sect (XXXXXXXXXXXXXX)
   00.23: NETAPP   X371_S1643960ATE NA54 915.4GB 520B/sect (XXXXXXXXXXXXXX)
    Shelf 0: DS224-12  Firmware rev. IOM12E A: 0240  IOM12E B: 0240
       
slot 0: SAS Host Adapter 0b (PMC-Sierra PM8070 rev. C, SAS, <UP>)
    [...]
    00.20: NETAPP   X371_S1643960ATE NA54 915.4GB 520B/sect (XXXXXXXXXXXXXX)
    00.21: NETAPP   X371_S1643960ATE NA54 915.4GB 520B/sect (XXXXXXXXXXXXXX)
    00.22: NETAPP   X371_S1643960ATE NA54 915.4GB 520B/sect (XXXXXXXXXXXXXX)
    Shelf 0: DS224-12  Firmware rev. IOM12E A: 0240  IOM12E B: 0240
  • Bay 在 SAS 扩展器 phy 状态中显示为 Disabled/IDD

Node01> sasadmin expander_phy_state
Expander phy state on 0b.0 (NETAPP  :DS22412IOM12E    SHFHUXXXXXXXXXXX):
                              Pwr         Invald Disprt Loss   Phy    CRC    Phy                   
                          Pwr Ccl Rsv Rls DWord  Error  Sync   Reset  Error  Change SATA           
PHY/BAY STATE             ON  Cnt Cnt Cnt Count  Count  Count  Prob   Cnt    Cnt    Affiliation    
------- ----------------- --- --- --- --- ------ ------ ------ ------ ------ ------ ----------------
29/21   12.0 Gb/s         YES 0   0   0   0      0      0      0      0      1      ----------------
30/22   12.0 Gb/s         YES 0   0   0   0      0      0      0      0      1      ----------------
31/23  Disabled/IDD      YES 0   0   0

  • 磁盘显示 BYPASSED B

Disk Elements:
Element Status          Status Bytes  Status Descriptions
  0 [Bay  0]: OK         01,00,00,00
  1 [Bay  1]: NONCRITICAL     03,01,10,04  ENCLOSURE BYPASSED B, BYPASSED B

  • 在某些情况下,"sysconfig -A" 显示 "Mixed-Path HA" 
    • System Storage Configuration: Mixed-Path HA
  • 在 ADP 配置中,对于无法看到磁盘的节点可能看不到分区

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.