ONTAP 9 回馈操作被密钥管理器否决
适用于
- ONTAP 9
- 板载密钥管理器(OKM)
- NetApp 卷加密(NVE)
- NetApp 聚合加密(NAE)
- 回交操作
- NDU 暂停操作
问题
- 存储交还操作被否决。
- 如果运行 ONTAP NDU,暂停错误可能会显示 SFO 聚合交还问题:
Error: Giveback of SFO aggregate is vetoed., Action: Use the "storage failover show-giveback" command to view the detailed veto status information. Correct the vetoed subsystem. Use the "storage failover giveback -ofnode <node>" command to complete the giveback.
-
Storage failover show-giveback表示交还被 keymanager 否决:
::*> storage failover show-giveback
Partner
Node Aggregate Giveback Status
-------------- ----------------- ---------------------------------------------
<node1>
CFO Aggregates Done
aggr1
Failed: Operation was vetoed by keymanager.
Check the event log
- 事件日志显示可能存在 gb.sfo.veto.kmgr.keymissing 错误:
::*> event log show -node * -event gb*
Time Node Severity Event
------------------- ---------------- ------------- ---------------------------
<Time> <node> ERROR gb.sfo.veto.kmgr.keysmissing: Giveback of aggregate aggr1 failed due to unavailability of volume encryption keys for the encrypted volumes of the aggregate on the partner node
ALERT crypto.import.failed: ERROR: Import of key with key ID <key> failed. Additional information: wrapping key not found.
ALERT sfo.sendhome.subsystemAbort: The giveback operation of '<aggr>' was aborted by 'keymanager'