问题描述
storage disk show
命令引发错误、指出- "This array LUN is only available on one path. Proper configuration requires two paths
- FC启动程序端口直接连接到E系列存储。
- 对于使用E系列存储直接连接的FlexArray存储、阵列LUN仅显示在三个路径上、而不是显示在四个路径上。
FAS8200::> storage disk show -disk NET-1.35 -instance
Disk: NET-1.35
Container Type: aggregate
Owner/Home: FAS8200 / FAS8200
DR Home: -
Stack ID/Shelf/Bay: - / - / -
LUN: 36
Array: NETAPPARRAY
Vendor: NETAPP
Model: INF-01-00
Serial Number: 6D039EA00003564E000001xxxxxxxxxx
UID: 6D039EA0:000xxxxx:000xxxxx:5Fxxxxxx:00000000:00000000:00000000:00000000:00000000:00000000
BPS: 512
Physical Size: 2.19TB
Position: data
Checksum Compatibility: block
Aggregate: aggrx
Plex: plex0
Paths: LUN Initiator Side Target Side Link
Controller Initiator ID Switch Port Switch Port Acc Use Target Port TPGN Speed I/O KB/s IOPS
------------------ --------- ----- -------------------- -------------------- --- --- -----------------------
FAS8200-02 1c 36 N/A N/A AO INU 2023d039ea0356xx 0 16 Gb/S 3 0
FAS8200-01 1c 36 N/A N/A AO INU 2013d039ea0356xx 1 16 Gb/S 0 0
FAS8200-01 0g 36 N/A N/A ANO RDY 2012d039ea0356xx 0 16 Gb/S 0 0
Errors:
NET-1.35 (6d039ea00003564e000001385xxxxxxx): This array LUN is only available on one path. Proper configuration requires two paths.
- 尽管指向另一个FlexArry节点(即节点:1)的路径存在冗余路径、但仍反映了上述错误。
- FlexArray存储上的所有启动程序端口均已启动并联机。
ucadmin show
输出显示了在NetApp端已正确配置为启动程序端口的端口。
<<输出被截断>>
FAS8200::> system hardware unified-connect show
Current Current Pending Pending Admin
Node Adapter Mode Type Mode Type Status
------------ ------- ------- --------- ------- --------- -----------
FAS8200-01
0g fc initiator - - online
FAS8200-01
0h fc initiator - - offline
FAS8200-01
1c fc initiator - - online
FAS8200-01
1d fc initiator - - offline
FAS8200-02
0g fc initiator - - online
FAS8200-02
0h fc initiator - - offline
FAS8200-02
1c fc initiator - - online
FAS8200-02
1d fc initiator - - offline
node run -node FAS8200-02 -command sysconfig -a
输出不会反映Node:2的端口0g下的任何磁盘。
slot 0: FC Host Adapter 0g (QLogic 8324 rev. 2, N-port, <UP>)
Firmware rev: 8.9.1
Flash rev: 5.0.2
Host Port Id: 0xef
FC Node Name: 5:00a:09820e:c66xxx
FC Port Name: 5:00a:09820e:c66xxx
SFP Vendor: EMULEX
SFP Part Number: AFBR-57F5MZ-xx
SFP Serial Number: AA1850J1xxx
SFP Capabilities: 4, 8 or 16 Gbit
Link Data Rate: 16 Gbit
slot 1: FC Host Adapter 1c (Emulex XE201 rev. 48, N-port, <UP>)
Board name: 111-02451
Serial Number: FP92696xxx
Firmware rev: 12.4.320.0
Host Port Id: 0x1
FC Node Name: 2:000:00109b:872xxx
FC Port Name: 1:000:00109b:872xxx
SFP Vendor: FINISAR CORP.
SFP Part Number: FTLF8529P4BCVxxx
SFP Serial Number: P1HBXGA
SFP Capabilities: 4, 8 or 16 Gbit
Link Data Rate: 16 Gbit
124L1 : NETAPP INF-01-00 0880 908.3GB 512B/sect (6D039EA000035554000000BC5FB89046)
124L2 : NETAPP INF-01-00 0880 908.3GB 512B/sect (6D039EA00003564E000000A45FB89082)
124L3 : NETAPP INF-01-00 0880 443.5GB 512B/sect (6D039EA00003564E000000A65FB892F3)
124L4 : NETAPP INF-01-00 0880 443.5GB 512B/sect (6D039EA000035554000000C15FB892C5)
124L5 : NETAPP INF-01-00 0880 2289.1GB 512B/sect (6D039EA00003564E000001195FBB2580)
124L6 : NETAPP INF-01-00 0880 2289.1GB 512B/sect (6D039EA0000355540000012A5FBB2739)
- 在直接连接到FlexArray存储的E系列控制器上观察到琥珀色LED。
- 已执行FC启动程序端口的换用、但问题描述仍存在。
注意: 命令— node run -node <node-name> storage disable adapter <adapter>
可运行以禁用FC启动程序端口、也 node run -node <node-name> storage enable adapter <adapter>
可运行以启用FC启动程序端口。