跳转到主内容

由于在E系列框上映射问题描述、FlexArray上出现"此阵列LUN仅在一个路径上可用"错误

Views:
3
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
san<a>2010008810</a>
Last Updated:

适用场景

  • ONTAP
  • FlexArray
  • E系列

问题描述

  • storage disk show 命令引发错误、指出-  "This array LUN is only available on one path. Proper configuration requires two paths
  • FC启动程序端口直接连接到E系列存储。
  • 对于使用E系列存储直接连接的FlexArray存储、阵列LUN仅显示在三个路径上、而不是显示在四个路径上。

FAS8200::> storage disk show -disk NET-1.35 -instance

                  Disk: NET-1.35
        Container Type: aggregate
            Owner/Home: FAS8200 / FAS8200
               DR Home: -
    Stack ID/Shelf/Bay: -  / -  / -
                   LUN: 36
                 Array: NETAPPARRAY
                Vendor: NETAPP
                 Model: INF-01-00
         Serial Number: 6D039EA00003564E000001xxxxxxxxxx
                   UID: 6D039EA0:000xxxxx:000xxxxx:5Fxxxxxx:00000000:00000000:00000000:00000000:00000000:00000000
                   BPS: 512
         Physical Size: 2.19TB
              Position: data
Checksum Compatibility: block
             Aggregate: aggrx
                  Plex: plex0
Paths:                                LUN  Initiator Side        Target Side          Link
Controller  Initiator  ID  Switch Port  Switch Port   Acc Use  Target Port      TPGN  Speed    I/O KB/s    IOPS
------------------ ---------  -----  --------------------  --------------------  --- ---  -----------------------  
FAS8200-02     1c     36  N/A        N/A        AO  INU  2023d039ea0356xx   0  16 Gb/S     3       0
FAS8200-01     1c      36  N/A        N/A             AO  INU  2013d039ea0356xx   1  16 Gb/S     0       0
FAS8200-01     0g     36  N/A        N/A     ANO    RDY  2012d039ea0356xx   0  16 Gb/S     0       0

 

Errors:
NET-1.35 (6d039ea00003564e000001385xxxxxxx): This array LUN is only available on one path. Proper configuration requires two paths.

 

  • 尽管指向另一个FlexArry节点(即节点:1)的路径存在冗余路径、但仍反映了上述错误。
  • FlexArray存储上的所有启动程序端口均已启动并联机。
  • ucadmin show 输出显示了在NetApp端已正确配置为启动程序端口的端口。

<<输出被截断>>

FAS8200::> system hardware unified-connect show
            Current  Current   Pending  Pending   Admin
Node      Adapter  Mode    Type     Mode    Type     Status
------------  -------  -------  ---------  -------  ---------  -----------
FAS8200-01
       0g     fc     initiator  -     -      online
FAS8200-01
        0h     fc     initiator  -     -      offline
FAS8200-01
        1c     fc     initiator  -     -      online
FAS8200-01
        1d     fc     initiator  -     -      offline

FAS8200-02
        0g     fc     initiator  -     -      online
FAS8200-02
        0h     fc     initiator  -     -      offline
FAS8200-02
        1c     fc     initiator  -     -      online
FAS8200-02
        1d     fc     initiator  -     -      offline

  • node run -node FAS8200-02 -command sysconfig -a 输出不会反映Node:2的端口0g下的任何磁盘。

slot 0: FC Host Adapter 0g (QLogic 8324 rev. 2, N-port, <UP>)
       Firmware rev:    8.9.1
       Flash rev:      5.0.2
       Host Port Id:    0xef
       FC Node Name:    5:00a:09820e:c66xxx
       FC Port Name:    5:00a:09820e:c66xxx
       SFP Vendor:     EMULEX
       SFP Part Number:   AFBR-57F5MZ-xx
       SFP Serial Number: AA1850J1xxx
       SFP Capabilities:  4, 8 or 16 Gbit
       Link Data Rate:   16 Gbit

slot 1: FC Host Adapter 1c (Emulex XE201 rev. 48, N-port, <UP>)
       Board name:     111-02451
       Serial Number:    FP92696xxx
       Firmware rev:    12.4.320.0
       Host Port Id:    0x1
       FC Node Name:    2:000:00109b:872xxx
       FC Port Name:    1:000:00109b:872xxx
       SFP Vendor:     FINISAR CORP.
       SFP Part Number:   FTLF8529P4BCVxxx
       SFP Serial Number: P1HBXGA
       SFP Capabilities:  4, 8 or 16 Gbit
       Link Data Rate:   16 Gbit
       124L1   : NETAPP   INF-01-00     0880 908.3GB 512B/sect (6D039EA000035554000000BC5FB89046)
       124L2   : NETAPP   INF-01-00     0880 908.3GB 512B/sect (6D039EA00003564E000000A45FB89082)
       124L3   : NETAPP   INF-01-00     0880 443.5GB 512B/sect (6D039EA00003564E000000A65FB892F3)
       124L4   : NETAPP   INF-01-00     0880 443.5GB 512B/sect (6D039EA000035554000000C15FB892C5)
       124L5   : NETAPP   INF-01-00     0880 2289.1GB 512B/sect (6D039EA00003564E000001195FBB2580)
       124L6   : NETAPP   INF-01-00     0880 2289.1GB 512B/sect (6D039EA0000355540000012A5FBB2739)
    

  • 在直接连接到FlexArray存储的E系列控制器上观察到琥珀色LED。

Amber-led-eseries.png
 

  • 已执行FC启动程序端口的换用、但问题描述仍存在。

注意: 命令— node run -node <node-name> storage disable adapter <adapter> 可运行以禁用FC启动程序端口、也  node run -node <node-name> storage enable adapter <adapter> 可运行以启用FC启动程序端口。

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.