跳转到主内容

由于交换机间链路故障、无法访问卷事件

Views:
4
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
san<a>2009965120</a>
Last Updated:

适用场景

  • ONTAP 9
  • SnapMirror活动同步(SMA)
  • Brocade FC 交换机
  • 两个站点通过交换机间链路(ISL)连接
  • VMware ESXi

问题描述

  • VMware显示间歇性丢失对卷的访问事件:
Lost access to volume 63864940-ca00f732-af03-0025b511000e (example_ds1) due to connectivity issues. Recovery attempt is in progress and outcome will be reported shortly.
Successfully restored access to volume 63864940-ca00f732-af03-0025b511000e (example_ds1) following connectivity issues.
  • EMS会记录仅影响集群另一站点的主机的光纤通道问题,如所记录的中所示 S_ID

[cluster1_node1: fct_tpd_work_thread_0: fcp.io.status:debug]: STIO Adapter:2b IO WQE failure, Handle 0x1, Type 8, S_ID: 16210D, VPI: 130, OX_ID: 46D8, Status 0x3 Ext_Status 0x16
[cluster1_node1: fct_tpd_thread_1: fcp.io.status:debug]: STIO Adapter:2b, found hung cmd:0xfffff8042aea04b0(state=5, flags=0x0, ctio_sent=1/1,RecvExAddr=0x14c7, OX_ID=0x4947, RX_ID=0xffff,SID=0x16210d, Cmd[2A], req_q_free:0)   
[cluster1_node2: fct_tpd_thread_1: fcp.io.status:debug]: STIO Adapter:2b, found hung cmd:0xfffff8042af79d28(state=5, flags=0x0, ctio_sent=1/1,RecvExAddr=0x16b0, OX_ID=0x4fb7, RX_ID=0xffff,SID=0x16190b, Cmd[2A], req_q_free:0)
[cluster2_node1: fct_tpd_thread_1: fcp.io.status:debug]: STIO Adapter:2b, found hung cmd:0xfffff804254b0478(state=5, flags=0x0, ctio_sent=1/1,RecvExAddr=0x1666, OX_ID=0x44ce, RX_ID=0xffff,SID=0xc2109, Cmd[2A], req_q_free:0)
[cluster2_node1: fct_tpd_thread_1: fcp.io.status:debug]: STIO Adapter:2b, found hung cmd:0xfffff80425401d10(state=5, flags=0x0, ctio_sent=1/1,RecvExAddr=0x1568, OX_ID=0x4291, RX_ID=0xffff,SID=0xc2109, Cmd[2A], req_q_free:0)
[cluster2_node2: fct_tpd_work_thread_0: fcp.io.status:debug]: STIO Adapter:2b IO WQE failure, Handle 0x1, Type 8, S_ID: 16210D, VPI: 130, OX_ID: 4273, Status 0x3 Ext_Status 0x11

  • 一台交换机显示ISL接收功率低:
RX Power: -6.1 dBm (245.0uW)
TX Power: 0.4 dBm (1093.9 uW)
  • ISL另一端的电源正常:
RX Power:   -2.8   dBm (523.9uW)
TX Power:   -0.2   dBm (949.3 uW)
  • 如果主机上的VM通过ISL访问另一站点上的数据存储库、则生产会受到影响

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.