FCP FCoE LIF报告运行中断、并显示扩展状态FISC错误
适用场景
- ONTAP
- FCP/FCoE LIF
问题描述
- LIF为
admin UP
、但operationally down
处于扩展状态-"FDISC error - ID could not be acquired for this virtual port"
- 托管LIF的适配器处于联机状态。
- 在
EMS
日志中为相关适配器报告以下事件:
[DC_FAS8700-01: fct_tpd_thread_1: fcp.io.status:debug]: STIO Adapter:1b, found hung cmd:0xfffff80ec6ad47e0(state=10, flags=0x2,ctio_sent=2/2,RecvExAddr=0x1911, OX_ID=0xa18, RX_ID=0xffff,SID=0x247xx, Cmd[28],req_q_free:0[DC_FAS8700-01: fct_tpd_thread_1: scsitarget.fct.reset:notice]: Resetting Fibre Channel target adapter 1b.
[FAS8700-01: fct_tpd_work_thread_0: scsitarget.hwpfct.linkUp:notice]: Link up on Fibre Channel target adapter 1b.
[?] Wed Jun 12 11:45:12 +0000 [DC_FAS8700-01: fct_tpd_work_thread_0: scsitarget.slifct.wqeError:debug]: FC port 1b has a WQE processing failure of type SLI_ELS_REQ, command PLOGI, subtype x0, with status of 3 and an extended status x2 for NPIV port 0.
[?] Wed Jun 12 11:45:12 +0000 [DC_FAS8700-01: fct_tpd_work_thread_0: scsitarget.slifct.wqeError:debug]: FC port 1b has a WQE processing failure of type SLI_ELS_REQ, command FDISC, subtype x0, with status of 3 and an extended status x2 for NPIV port 1.
- 如果此端口已连接到Brocade交换机、请检查每端口NPIV登录限制(请参见"
portcfgshow
"中的"NPIV PP Limit
")是否设置为零或值太低、无法允许所有LIF登录。 - 如果需要修改此值,我们可以Brocade使用"
portCfgDefault
”(注- 此操作将覆盖所有端口设置)。 或者、我们 也可以使用专门设置登录限制 " portcfgnpivport --setloginlimit
" 对于 portcfgshow
中的相关端口,NPIV限制设置为126:
Ports of Slot 0 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63
------------------------+---+---+---+---+-----+---+---+---+-----+---+---+---+-----+---+---+---
NPIV capability ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON
NPIV PP Limit 126 126 126 126 126 126 126 126 126 126 126 126 126 126 126 126