FCP/FCoE LIF 报告由于交换机 SFP 故障导致运行中断
适用于
- ONTAP 9
- FCP 或 FCoE
- Cisco 交换机
- Brocade 交换机
问题描述
- 启动程序无法连接到 FCP LIF 或访问该 LIF 所呈现的 LUN。
Network interface show输出将 FCP LIF 的状态报告为管理上启用但操作上关闭。
cluster1::> network interface show -data-protocol fcp
Logical Status Network Current Current Is
Vserver Interface Admin/Oper Address/Mask Node Port Home
----------- ---------- ---------- ------------------ ------------- ------- ----
fcp-svm
fcp-lif up/down 20:03:00:a0:xx:xx:xx:xx cluster1-01 0f true
Network fcp adapter show输出将适配器状态报告为"Link disconnected""。
Cluster1::> network fcp adapter show –fields status
node adapter status
------------- ------- ------
Cluster1-01 0f link disconnected
SYSCONFIG-A输出将状态显示为"Link disconnected"。
slot 0: Fibre Channel Target Host Adapter 0f
(QLogic 8324 (8362) rev. 2, <LINK DISCONNECTED>)
Firmware rev: 8.9.0
Flash rev: 5.0.2
Host Port Addr: 000000
FC Nodename: 50:0a:09:80:xx:xx:xx:xx(500a0980xxxxxxxx)
FC Portname: 50:0a:09:81:xx:xx:xx:xx(500a0981xxxxxxxx)
Connection: No link
Switch Port: Unknown
SFP Vendor Name: AVAGO
SFP Vendor P/N: AFBR-57F5MZ-NA1
SFP Vendor Rev: 01
SFP Serial No.: xxxxxxxxx
SFP Connector: LC
SFP Capabilities: 4, 8, 16 Gbit/Sec
show interface transceiver输出报告受影响的存储连接端口的低 Tx 功率。