事件摘要
当集群交换机上有风扇电源时,会发送 SwitchPsuFanNotOperational_Alert,但是虽然风扇电源指示其运行正常,风扇状态本身却指示风扇未运行。
验证
AutoSupport 消息
HA Group Notification from Node Name (Health Monitor process cshm: SwitchPsuFanNotOperational_Alert[Switch Name(Serial Numer)/PowerSupply-1 Fan-1]) ALERT
EMS 日志
event log show -severity * -message-name callhome*
[node1: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process cshm: SwitchPsuFanNotOperational_Alert[Switch_Name(########)/PowerSupply-2 Fan-1].
命令行
system health alert show -node <node name> -monitor cluster-switch -alert-id SwitchPsuFanNotOperational
Node: Node01
Monitor: cluster-switch
Class of Alert: SwitchPsuNotOperational_Alert
Severity of Alert: Major
Probable Cause: Out_of_service
Probable Cause Description: "Fan Module-3" on switch "Switch Name(Switch Name)" is not functioning properly.
Possible Effect: Cooling of switch "Switch Name(Serial Number)" might be degraded.
Corrective Actions: 1) Use the switch CLI to verify that the fan is functioning at the expected speed. 2) Replace the fan, if it is not operational.