跳转到主内容

SwitchPsuFanNotOperational_Alert - AutoSupport 消息

Views:
37
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches
Specialty:
hw
Last Updated:

适用于

  • ONTAP 9
    • Metrocluster Fabric 交换机
    • 集群网络交换机
    • NetApp 集群交换机
    • Broadcom 交换机
    • Cisco 交换机
  • callhome.hm.alert.major
    • Health Monitor 进程 cshm 的 Call home:SwitchPsuFanNotOperational_Alert

事件摘要

当集群交换机上有风扇电源时,会发送 SwitchPsuFanNotOperational_Alert,但是虽然风扇电源指示其运行正常,风扇状态本身却指示风扇未运行。 

验证

AutoSupport 消息

HA Group Notification from Node Name (Health Monitor process cshm: SwitchPsuFanNotOperational_Alert[Switch Name(Serial Numer)/PowerSupply-1 Fan-1]) ALERT

EMS 日志

event log show -severity * -message-name callhome*

[node1: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process cshm: SwitchPsuFanNotOperational_Alert[Switch_Name(########)/PowerSupply-2 Fan-1].

命令行

system health alert show -node <node name> -monitor cluster-switch -alert-id SwitchPsuFanNotOperational

            Node: Node01
          Monitor: cluster-switch
       Class of Alert: SwitchPsuNotOperational_Alert
     Severity of Alert: Major
       Probable Cause: Out_of_service
Probable Cause Description: "Fan Module-3" on switch "Switch Name(Switch Name)" is not functioning properly.
      Possible Effect: Cooling of switch "Switch Name(Serial Number)" might be degraded.
     Corrective Actions: 1) Use the switch CLI to verify that the fan is functioning at the expected speed.                      2) Replace the fan, if it is not operational. 

解决方法

  1. 确认电源已安装。
  2. 确认电源正在接通电源。
  3. 如果确定电源有缺陷,请更换电源。
    • 对于 Brocade 交换机,请联系 NetApp 技术支持 获得帮助。
    • 对于 Cisco 交换机,请联系 Cisco 以获得帮助

注意:如果这是计划维护活动的一部分,请更新相应的 NetApp 支持案例 

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.