SwitchPsuFanNotOperational_Alert - AutoSupport 消息
适用于
- ONTAP 9
- Metrocluster Fabric 交换机
- 集群网络交换机
- NetApp 集群交换机
- Broadcom 交换机
- Cisco 交换机
- callhome.hm.alert.major
- Health Monitor 进程 cshm 的 Call home:SwitchPsuFanNotOperational_Alert
事件摘要
当集群交换机上有风扇电源时,会发送 SwitchPsuFanNotOperational_Alert,但是虽然风扇电源指示其运行正常,风扇状态本身却指示风扇未运行。
验证
AutoSupport 消息
HA Group Notification from Node Name (Health Monitor process cshm: SwitchPsuFanNotOperational_Alert[Switch Name(Serial Numer)/PowerSupply-1 Fan-1]) ALERT
EMS 日志
event log show -severity * -message-name callhome*
[node1: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process cshm: SwitchPsuFanNotOperational_Alert[Switch_Name(########)/PowerSupply-2 Fan-1].
命令行
system health alert show -node <node name> -monitor cluster-switch -alert-id SwitchPsuFanNotOperational
Node: Node01
Monitor: cluster-switch
Class of Alert: SwitchPsuNotOperational_Alert
Severity of Alert: Major
Probable Cause: Out_of_service
Probable Cause Description: "Fan Module-3" on switch "Switch Name(Switch Name)" is not functioning properly.
Possible Effect: Cooling of switch "Switch Name(Serial Number)" might be degraded.
Corrective Actions: 1) Use the switch CLI to verify that the fan is functioning at the expected speed. 2) Replace the fan, if it is not operational.
解决方法
- 确认电源已安装。
- 确认电源正在接通电源。
- 如果确定电源有缺陷,请更换电源。
- 对于 Brocade 交换机,请联系 NetApp 技术支持 获得帮助。
- 对于 Cisco 交换机,请联系 Cisco 以获得帮助
注意:如果这是计划维护活动的一部分,请更新相应的 NetApp 支持案例