SwitchPsuFanNotOperational_Alert—AutoSupport 消息
适用场景
- ONTAP 9
- MetroCluster光纤交换机
- 集群网络选择
- NetApp集群交换机
- Broadcom交换机
- Cisco 交换机
- CallHome.hm.alAlert.Major
- 运行状况监控进程cshm: SwitchPsuFanNotOperational _Alert、请致电主页
事件摘要
如果集群交换机上的风扇有电源、则会发送SwitchPsuFanNotOperational _Alert、但当风扇的电源指示它正在运行时、风扇状态本身指示风扇未运行时、则会发送SwitchPsuFanNotOperational _Alert。
验证
AutoSupport 消息
HA Group Notification from Node Name (Health Monitor process cshm: SwitchPsuFanNotOperational_Alert[Switch Name(Serial Numer)/PowerSupply-1 Fan-1]) ALERT
EMS日志
event log show -severity * -message-name callhome*
[node1: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process cshm: SwitchPsuFanNotOperational_Alert[Switch_Name(########)/PowerSupply-2 Fan-1].
命令行
system health alert show -node <node name> -monitor cluster-switch -alert-id SwitchPsuFanNotOperational
Node: Node01
Monitor: cluster-switch
Class of Alert: SwitchPsuNotOperational_Alert
Severity of Alert: Major
Probable Cause: Out_of_service
Probable Cause Description: "Fan Module-3" on switch "Switch Name(Switch Name)" is not functioning properly.
Possible Effect: Cooling of switch "Switch Name(Serial Number)" might be degraded.
Corrective Actions: 1) Use the switch CLI to verify that the fan is functioning at the expected speed. 2) Replace the fan, if it is not operational.
解决方法
- 验证是否已安装电源。
- 验证电源是否通电。
- 如果确定电源有故障、请更换电源。
- 对于Brocade交换机、请联系 NetApp技术支持 以获得帮助。
- 对于Cisco交换机、请联系 Cisco 以获得帮助
- 对于CN1610交换机、请联系 NetApp技术支持 以获得帮助。
- 注意:如果这是计划内维护活动的一部分、请更新相关的 NetApp支持案例