问题描述

  • 收到标题为DR配置复制失败错误的AutoSupport
  • 在ASUP文件'SVM-vserver.xml'或命令MetroCluster vserver show中、一个或多个MetroCluster降级并显示以下错误:

ClusterB::> metrocluster vserver show
...
              Cluster  : ClusterA
                Vserver  : SVM1A
            Partner Vserver  : SVM1A-mc
          Configuration State  : degraded
             Stream Status  : operation-failed
           Corrective Action  : Resynchronize the configuration using "metrocluster vserver resync" command. Contact technical support for assistance if configuration-state does not change to healthy.
               Failed Row : Table Name: publickey_ui, Operation: get, Fields: ...
             Failed Reason : Apply failed for Object: publickey_ui Method: baseline. Reason: duplicate entry

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.