在BMC命令行界面中看不到系统关闭和多个传感器信息

Views:
28
Visibility:
Public
Votes:
0
Category:
fas-systems<a>2009年23月24日55</a>
Specialty:
hw
Last Updated:

适用场景

FAS500F

问题描述

  • 在node-02中检测到IOM12E模块故障并从node-01接管。

EMS 日志:

</LR>
<LR d="09Jul2022 07:22:00" n="node-01" t="1657318920" id="1655365394/8541" p="0" s="Ok" o="monitor" vf="" type="0" seq="75705">
<monitor_globalStatus_critical_1
     problem="This node has taken over node-02. "/>
</LR>
<LR d="09Jul2022 07:22:11" n="node-01" t="1657318931" id="1655365394/8542" p="3" s="Ok" o="dsa_worker0" vf="" type="0" seq="75706">
<ses_status_electronicsWarn_1
     prodChannel="NS224NSM8E (S/N SHJSGXXXXXXXXXX) shelf 0 on channel 0s"
     typeText="SES electronics"
     electrNumber="2"
     warningMsg="communication error"
     warningText="; enclosure services hardware failed"
     locationText="This element is on the rear of the shelf at the bottom, on shelf module (B)"/>
</LR>
<LR d="09Jul2022 07:22:11" n="node-01" t="1657318931" id="1655365394/8543" p="1" s="Ok" o="dsa_worker0" vf="" type="0" seq="75707">
<ses_status_ModuleError_1
     prodChannel="NS224NSM8E (S/N SHJSGXXXXXXXXXX) shelf 0 on channel 0s"
     moduleType="PCI switch"
     typeText="PCI Switch"
     ModuleNumber="2"
     errorMsg="status not available"
     errorText="; status not available"
     locationText="This element is on the rear of the shelf at the bottom, on shelf module (B)"/>

  • 接管后、从DOWN node-02端的BMC命令行界面IPMI传感器显示为"na"状态、无法启动。

SP最新IPMI:

=================== sensor ==========================
Sensor name    | reading   | unit     | status| lnr     | lcr     | lnc     | unc     | ucr     | unr
PVCCIN_CPU_FD   | na     | Volts    | na  | na    | 0.490    | 0.784    | 2.195    | 2.391    | na
PVCCSA_CPU_FD   | na     | Volts    | na  | na    | 0.297    | 0.396    | 1.485    | 1.683    | na
PVDDQ_AB_FD    | na     | Volts    | na  | na    | 0.488    | 0.799    | 1.482    | 1.697    | na
PVDDQ_CD_FD    | na     | Volts    | na  | na    | 0.488    | 0.799    | 1.482    | 1.697    | na
PVNN_PCH_AFD    | na     | Volts    | na  | na    | 0.268    | 0.474    | 1.175    | 1.216    | na
P0V9_PLX0_F    | na     | Volts    | na  | na    | 0.293    | 0.741    | 1.190    | 1.248    | na
P0V9_PLX1_F    | na     | Volts    | na  | na    | 0.293    | 0.741    | 1.190    | 1.248    | na
P3V_BAT      | na     | Volts    | na  | na    | 2.340    | 2.652    | 3.276    | 3.354    | na

 


Bat_Dstg_Cycles  | na     | cycles    | na  | na    | 2.000    | 5.000    | na    | na    | na
Bat_Cycle_Cnt   | na     | cycles    | na  | na    | na    | na    | na    | na    | na
Bat_Power_Fault  | na     | discrete   | na  | na    | na    | na    | na    | na    | na
Bat_Dsg_FET_Flt  | na     | discrete   | na  | na    | na    | na    | na    | na    | na
Bat_Chg_FET_Flt  | na     | discrete   | na  | na    | na    | na    | na    | na    | na
Bat_Pack_Invalid | na     | discrete   | na  | na    | na    | na    | na    | na    | na
Bat_Lrn_Active   | na     | discrete   | na  | na    | na    | na    | na    | na    | na
FRU Presence    | na     | discrete   | na  | na    | na    | na    | na    | na    | na

 

  • 从BMC重新启动受损节点-02、但无法启动。

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.