vifmgr.ifs.overCapacity:故障转移目标配置过度的节点
适用场景
- FAS 系统
- AFF系统
- ONTAP 9
问题描述
- 事件日志在中报告以下警报
EMS-logs
:
NodeName: vifmgr: vifmgr.lifs.overcapacity:alert]: Node with failover targets over-provisioned: XXX LIFs could be marked "down" during node outage.
NodeName: vifmgr: vifmgr.lifs.noredundancy:alert]: No redundancy in the failover configuration for X LIFs assigned to node "NodeName". LIFs: NodeName:NodeName
NodeName: vifmgr: vifmgr.lifs.overcapacity:alert]: Node with failover targets over-provisioned: XXX LIFs could be marked "down" during node outage.
NodeName: vifmgr: vifmgr.lifs.noredundancy:alert]: No redundancy in the failover configuration for X LIFs assigned to node "NodeName". LIFs: NodeName:NodeName
- 检查 [1] 以确定系统可以托管的每个节点和HA对的Hardware Universe数量
- 运行 以下命令 以验证当前的RIFs设置
::> set advanced
::*> net int capacity details show
(network interface capacity details show)
IP Data LIF IP Data LIF IP Data LIF
Node Capacity Supported Limit Count
----------------- --------------- --------------- ---------------
Node-01 512 512 350
Node-02 512 512 350
2 entries were displayed.