跳转到主内容

磁盘 ioRecoveredError 后出现 sas.device.timeout 错误

Views:
5
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw
Last Updated:

适用于

ONTAP 9

问题描述

  • IO 问题后会发生 IO 恢复。

 [?]  Tue Jul 23 17:25:02 +0900 [NodeA: disk_server_0: disk.ioRecoveredError.retry:info]: Recovered error on disk 0x.XX.XX: op 0x2f:37776800:0400 sector 0 SCSI:recovered error - Disk used internal retry algorithm to obtain data (1 b 4 0) (49) Disk 0x.XX.XX Shelf X Bay XX [NETAPP   X342_SSKBE1T2A10 NA02] S/N [XXXXXXXX] UID [X000XX00:XXXXXXXX:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]
 [?]  Tue Jul 23 17:25:02 +0900 [NodeA: disk_server_0: disk.IO.status:debug]: params: {'deviceName': '0x.XX.XX', 'ETime': '49', 'cdb': '0x2f:37776800:0400', 'victimRetryCount': '0', 'retryCount': '0', 'timeoutRetryCount': '0', 'pathRetryCount': '0', 'adapterStatus': '0x0', 'targetStatus': '0x2', 'sSenseKey': 'SCSI:recovered error', 'sSenseCode': '', 'iSenseKey': '0x1', 'iASC': '0xb', 'iASCQ': '0x4', 'pathsTried': '1', 'basicTimeout': '5', 'returnCode': '5', 'disk_information': 'Disk 0x.XX.XX Shelf X Bay XX [NETAPP   X342_SSKBE1T2A10 NA02] S/N [XXXXXXXX] UID [X000XX00:XXXXXXXX:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]'}

  • 由于 IO 恢复错误,在维护中心运行磁盘测试。
    维护中心测试结果成功。

 [?]  Thu Jul 25 05:58:47 +0900 [NodeA: pmcsas_timeout_0: sas.device.timeout:error]: Adapter 0x encountered a device timeout on Disk device 0x.XX.XX.
 [?]  Thu Jul 25 05:59:02 +0900 [NodeA: disk_admin: disk.outOfService:notice]: Drive 0x.XX.XX (WFK8A82P): exceeded latency threshold. Power-On Hours: 32653, GList Count: 0, Drive Info: Disk 0x.XX.XX Shelf X Bay XX [NETAPP   X342_SSKBE1T2A10 NA02] S/N [XXXXXXXX] UID [X000XX00:XXXXXXXX:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000].
......
 [?]  Thu Jul 25 05:59:02 +0900 [NodeA: config_thread: raid.disk.maint.start:notice]: Disk /aggrX/plex0/rg1/0x.XX.XX Shelf X Bay XX [NETAPP   X342_SSKBE1T2A10 NA02] S/N [XXXXXXXX] UID [X000XX00:XXXXXXXX:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] will be tested.
......
 [?]  Thu Jul 25 10:33:22 +0900 [NodeA: config_thread: raid.disk.maint.done:notice]: Disk 0x.XX.XX Shelf X Bay XX [NETAPP   X342_SSKBE1T2A10 NA02] S/N [XXXXXXXX] UID [X000XX00:XXXXXXXX:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] tests were completed successfully.

  • 然后将该磁盘设置为备用磁盘以继续使用。
  • 以下 errorTrap 也可能发生。

#2 errorTrap <DC=[REDACTED] HOST=[REDACTED] IPADDRESS=[REDACTED] TAG_Resource=[REDACTED] xSLAkey=[errorTrap]>
[productTrapData.0 = sas.device.timeout:Adapter 1 encountered a device timeout on Disk device 1d.05.18.; productSerialNum.0 = 1-80-000011, [DC=REDACTED]]

#2 errorTrap <DC=[REDACTED] HOST=[REDACTED] IPADDRESS=[REDACTED] TAG_Resource=[REDACTED] xSLAkey=[errorTrap]>
[productTrapData.0 = scsi.cmd.abortedByHost:Disk device 1d.05.18: Command aborted by host adapter: HA status 0x4: cdb 0x2f:90e1ec00:0400. ; productSerialNum.0 = 1-80-000011, [DC=REDACTED]]

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.