raidio_thread: raid_rg_scrub_media_recommend_reassign_err_1
适用于
FAS 系统
问题描述
- 磁盘擦除发现恢复的错误后,会出现磁盘块重新分配错误:
Fri May 13 04:13:18 JST [nodename: disk_server_0: disk.ioRecoveredError.retry:info]: Recovered error on disk 0b.11.7: op 0x88:0000000381a31000:00000200 sector 15059849224 SCSI:recovered error - Disk used internal retry algorithm to obtain data (1 17 1 2c) (1054) Disk 0b.11.7 Shelf 11 Bay 7 [NETAPP X318_HARHE08TA07 NA00] S/N [R5GB0ESV]
Fri May 13 04:13:18 JST [nodename: raidio_thread: raid_rg_scrub_media_recommend_reassign_err_1:notice]: params: {'disk_rpm': '7200', 'vendor': 'NETAPP ', 'firmware_revision': 'NA00', 'shelf': '11', 'disk_info': 'Disk /nodename_aggr2/plex0/rg1/0b.11.7 Shelf 11 Bay 7 [NETAPP X318_HARHE08TA07 NA00] S/N [R5GB0ESV]', 'site': 'Local', 'bay': '7', 'carrier': '', 'serialno': 'R5GB0ESV', 'owner': '', 'model': 'X318_HARHE08TA07', 'disk_type': '8', 'blockNum': '1882481153'}
Wed Jul 23 01:00:37 +0900 [nodename: raidio_thread: raid_rg_readerr_repair_parity_1:notice]: params: {'owner': '', 'disk_info': 'Disk /mp_dos2_nas01_aggr0_01/plex0/rg0/0c.10.1 Shelf 10 Bay 1 [NETAPP X318_HARHE08TA07 NA01] S/N [R5GATR3V] UID [5000CCA2:6213A1EC:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]', 'blockNum': '5630', 'shelf': '10', 'bay': '1', 'vendor': 'NETAPP ', 'model': 'X318_HARHE08TA07', 'firmware_revision': 'NA01', 'serialno': 'R5GATR3V', 'disk_type': '8', 'disk_rpm': '7200', 'carrier': '', 'site': 'Local'}
- 几分钟后,磁盘块的重新分配成功:
Fri May 13 04:13:49 JST [nodename: disk_server_0: disk.ioReassignSuccess:notice]: disk 0b.11.7: sector 15059849224 was reassigned (446). Disk 0b.11.7 Shelf 11 Bay 7 [NETAPP X318_HARHE08TA07 NA00] S/N [R5GB0ESV]