跳转到主内容

写入验证错误:端口0x失败- AutoSupport 消息

Views:
6
Visibility:
Public
Votes:
0
Category:
aff-series
Specialty:
hw
Last Updated:

适用场景

  • ONTAP 9
  • callhome.HBA.failed

事件摘要

如果由于写入后读取验证错误而使HBA端口脱机、则会出现此消息。

验证

主叫事件
HA Group Notification from Node Name (Write Verification Error: Port 0a Failed) EMERGENCY
EMS日志

event log show -severity * -message-name callhome*

[Node Name: disk_admin: callhome.hba.failed:EMERGENCY]: Call home for Write Verification Error: Port 0a Failed

命令行

system node run -node <node name> -command sysconfig 

slot 0: SAS Host Adapter 0a (PMC-Sierra PM8070 rev. C, SAS, <OFFLINE (soft)>) Firmware rev: 03.08.09.00 Base WWN: 5:00axxx:xxxxxxx:xx Phy State: [0] Disabled [1] Disabled [2] Disabled [3] Disabled

解决方法

The solution might require a part replacement. Please contact NetApp Technical Support or log into the NetApp Support Site to create a case. Reference this article for further assistance.

警告

在未事先咨询NetApp支持的情况下、请勿尝试使适配器联机、否则、尝试使运行不正常的适配器联机可能会导致数据损坏。

 

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.

 

  • 这篇文章对您有帮助吗?