两个 HA 控制器都会在所有 SAS 端口脱机的情况下重复重新启动 立即启动
- Views:
- 49
- Visibility:
- Public
- Votes:
- 0
- Category:
- fas-systems<a>由于多个磁盘上的校验和验证失败而脱机</a>
- Specialty:
- hw
- Last Updated:
适用场景
- ONTAP 9
- disk.checksum.offlineAdapter
问题描述
控制器启动失败,并显示以下错误:
[localhost:disk.checksum.offlineAdapter:error]: Adapter 0a taken offline due to checksum verification failure on multiple disks.
[localhost:disk.checksum.offlineAdapter:error]: Adapter 0b taken offline due to checksum verification failure on multiple disks.
[localhost:config.noPartnerDisks:CRITICAL]: No disks were detected for the partner; this node will be unable to takeover correctly
如果所有SAS适配器脱机、则会出现以下附加错误:
WARNING: 0 disks found!
Storage Adapters found:
0 Fibre Channel Storage Adapters found!
2 SAS Adapters found!
Jun 29 17:20:39 [cluster1-01:cf.fm.noMBDisksOrIc:error]: Could not find the local mailbox disks. Could not determine the firmware state of the partner through the HA interconnect.
0 Parallel SCSI Storage Adapters found!
0 ATA Adapters found!
Select option 4 from the boot menu to choose disks for the root volume and spare core space.
Target Adapters found:
4 Fibre Channel Target Adapters found!
0 iSCSI Target Adapters found!
WARNING: there do not appear to be any disks attached to the system.
No root volume found.
Rebooting... (press ctrl-c during boot to break reboot loop)