系统显示磁盘架故障
适用于
- ONTAP 9
- FAS/AFF
问题描述
- 集群中的两个节点都报告 EMS 中的磁盘盘架故障
node 1 ERROR monitor.shelf.warning: Fault reported on disk storage shelf attached to channel 0b. Check fans, power supplies, disks, and temperature sensors.
node 2 ERROR monitor.shelf.warning: Fault reported on disk storage shelf attached to channel 0b. Check fans, power supplies, disks, and temperature sensors.
托架 0 外壳状态报告为故障,IOM A 有 VPD 故障:
Enclosure Status: non-critical
Channel: 0a
Shelf: 0
Shelf Type: DS224-12
Product Serial Number: SHFFXXXX76
Module Type: IOM12EEnclosure:
Element Status Status Bytes Status Descriptions
1: NONCRITICAL 03,00,02,00 FAILVendor Unique Element 83-IOM12E: (SAS)
Element Status Status Bytes Status Descriptions
1 [IOM12E A] : NONCRITICAL 03,0C,00,20 BACKPLANE VPD FAULT, MASTER, RESERVED
2 [IOM12E B] : OK 01,00,00,20 RESERVED这指向节点 node 2 的问题,因为控制器 A 被配置为此节点。
NetApp Release 9.16.1P4: Tue May 27 19:22:56 EDT 2025
System ID: 0XXX16 (node 2); partner ID: 0XXX16 (node 1)
System Serial Number: 9XXXXX40 (node 2)Controller: ANetApp Release 9.16.1P4: Tue May 27 19:22:56 EDT 2025
System ID: 0XXX16 (node 1); partner ID: 0XXX16 (node 2)
System Serial Number: 9XXXXX41 (node 1)Controller: BSP-LATEST-IPMI 日志指示机箱 LED 由 SAS 扩展器(Shelf)打开:
tag origin fld fault reason count time
---- ------- ---- ------------- ------ -----
1 bmc /chassis-1 SAS Expander has set the Chassis LED ON 1 Wed Oct 1 23:39:04 2025Fault Lights On:
/chassis-1