跳转到主内容

系统在发出 PSU 警报后出现多磁盘故障

Views:
1
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw
Last Updated:

适用于

  • AFF/FAS
  • SAS 连接

问题

  • 系统针对多个磁盘架报告多个 ses.status.psWarning:error 事件。示例: 
[node01: dsa_worker3: ses.status.psWarning:error]: DS212-12 (S/N SHJHUXXXXXXXXXX) shelf 1 on channel 0a power warning for Power supply 2: warning status; DC undervoltage. This module is on the rear of the shelf at the bottom right.
 
[node01: dsa_worker1: ses.status.psWarning:error]: DS212-12 (S/N SHJHUXXXXXXXXXX) shelf 5 on channel 0a power warning for Power supply 2: warning status; DC undervoltage. This module is on the rear of the shelf at the bottom right.
 
[node01: dsa_worker3: callhome.shlf.power.intr:error]: Call home for SHELF POWER INTERRUPTED
  • 环境监控器 env_mgr: monitor.chassisPowerSupply.degraded:notice报告错误
[node01: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 2 is degraded: PSU2 VOUT is Critical Low (0 mV)
[node01: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 2 is degraded: PSU2 IOUT is Critical Low (0 mA)
[node01: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 2 is degraded: PSU2 POUT is Critical Low (0 mW)
[node01: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 2 is degraded: PSU2 Curr IIN is Critical Low (0 mA)
[node01: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 2 is degraded: PSU2 Hot is Critical Low (0 C)
[node01: env_mgr: monitor.chassisPowerSupply.degraded:notice]: Chassis power supply 2 is degraded: PSU2 FAN is Critical Low (0 RPM)
[node01: env_mgr: monitor.chassisPowerSupply.off:notice]: Chassis power supply 2 off.
[node01: env_mgr: callhome.chassis.ps.degraded:error]: Call home for CHASSIS POWER SUPPLY DEGRADED: PS 2
  • 由于电源降级(磁盘架“丢失”),磁盘架的一条路径出现降级。
  • 受影响的 SAS 路径的 HBA 发生 I/O 错误
[node01: scsi_cmdblk_strthr_admin: scsi.cmd.selectionTimeout:error]: Disk device 0a.02.0: Adapter/target error: HA status 0x7: cdb 0x8f:00000001f3301000:00000400. Targeted device did not respond to requested I/O. I/O will be retried. Disk 0a.02.0 Shelf 2 Bay 0 [NETAPP  X380_WVAXE10TA07 NA01] S/N [VHGSWVPM] UID [5000CCA0:C82B747C:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]
[node01: scsi_cmdblk_strthr_admin: scsi.cmd.selectionTimeout:error]: Disk device 0a.02.1: Adapter/target error: HA status 0x7: cdb 0x28:983cde00:0078. Targeted device did not respond to requested I/O. I/O will be retried. Disk 0a.02.1 Shelf 2 Bay 1 [NETAPP  X380_WVAXE10TA07 NA01] S/N [VHGST4XM] UID [5000CCA0:C82B3CE4:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]
[node01: scsi_cmdblk_strthr_admin: scsi.cmd.selectionTimeout:error]: Disk device 0a.02.3: Adapter/target error: HA status 0x7: cdb 0x8f:00000001f3301800:00000400. Targeted device did not respond to requested I/O. I/O will be retried. Disk 0a.02.3 Shelf 2 Bay 3 [NETAPP  X380_WVAXE10TA07 NA01] S/N [VHGSX4LM] UID [5000CCA0:C82B78CC:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]
  • 受影响路径中的磁盘多次超时后,系统将声明磁盘缺失,从而导致多磁盘崩溃
[node01: config_thread: cf.multidisk.fatalProblem:error]: Node encountered a multidisk error or other fatal error while waiting to be taken over. aggr aggr1_N1: raid volfsm, fatal multi-disk error..  Raid type - raid_tec Group name plex0/rg1 state NORMAL. 12 disks failed in the group. Disk 0a.02.1 Shelf 2 Bay 1 [NETAPP  X380_WVAXE10TA07 NA01] S/N [VHGST4XM] UID [5000CCA0:C82B3CE4:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] error: no valid path to disk. Disk 0a.02.2 Shelf 2 Bay 2 [NETAPP  X380_WVAXE10TA07 NA01] S/N [VHGST4UM] UID [5000CCA0:C82B3CD8:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] error: disk does not exist. Disk 0a.02.3 Shelf 2 Bay 3 [NETAPP  X380_WVAXE10TA07 NA01] S/N [VHGSX4LM] UID [5000CCA0:C82B78CC:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] error: disk does not exist. Disk 0a.02.4 Shelf 2 Bay 4 [NETAPP  X380_WVAXE10TA07 NA01] S/N [VHGS921M] UID [5000CCA0:C82A5A44:00000000:00000000:00000000:00000000:00000000:00000000:0000.

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.