SwitchifisLDownwarn_alert 来自链路聚合 xx 的警报
状态信息
适用场景
- ONTAP 9.5P4
- CN1610
问题描述
将 ONTAP 升级到 9.5p4 后、您会看到以下运行状况监视器警报:
natestdal0505-ff::*> system health alert show
Node: netapp_node_01
Resource: Link Aggregate 10
Severity: Major
Indication Time: Thu May 16 15:44:16 2019
Suppress: false
Acknowledge: false
Probable Cause: The cable used to connect switch "netapp_switch_01/ Link
Aggregate 10" to the ISL port might be faulty.
Possible Effect: Cluster redundancy might be lost.
Corrective Actions: 1) Check whether the cable is fully inserted into the interface port on both ends.
2) Reconnect the ISL port using another cable. After
reconnecting it, verify whether the link of the ISL
port is up by executing the commands as per switch
configuration guide or by checking whether the Link
status LED is on.