跳转到主内容

NSM100 模块上的风扇陈旧错误状态发生原因错误故障 LED

Views:
74
Visibility:
Public
Votes:
0
Category:
disk-shelves<a>NS224</a><a>NSM100</a><a>2008861783</a>
Specialty:
hw
Last Updated:

适用场景

  • NS224 架
  • NSM100 模块

问题描述

  • 重新启动、重新拔插或更换后、NSM100模块中的琥珀色故障LED。
  • EMS警告:

ses.status.fanWarning:notice]: NS224NSM100 (S/N serial) shelf 0 on channel 0x cooling fan warning for Cooling element 1: not operating. This element is on the unknown location.

  • 输出system node run -node <node> -command storage show fault -v表示一个或多个风扇传感器正常、但出现故障
  • 示例:
Fans:
Element Status         Status Bytes  Status Descriptions
(...)
11: OK                01,02,86,61  FAIL
12: OK                01,02,79,21
13: OK                01,02,6D,21
14: OK                01,02,7A,21
15: OK                01,02,74,61  FAIL
(...)
  • 但是、风扇运行正常、已通过确认 system node run -node * -command environment status
  • 示例:
Cooling Unit installed element list: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20; with error: none
Cooling Units by element:
[1] 6540 RPM
[2] 6390 RPM
[3] 6650 RPM
(...)
[18] 8090 RPM
[19] 8010 RPM
[20] 8000 RPM
 
  • AutoSupport 部分 STORAGE-SHELF.XML 可能还会在 affecter NSM模块下显示错误类型Acpp

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.