NSM100 模块上的风扇陈旧错误状态发生原因错误故障 LED
适用场景
- NS224 架
- NSM100 模块
问题描述
- 重新启动、重新拔插或更换后、NSM100模块中的琥珀色故障LED。
- EMS警告:
ses.status.fanWarning:notice]: NS224NSM100 (S/N serial) shelf 0 on channel 0x cooling fan warning for Cooling element 1: not operating. This element is on the unknown location.
- 输出
system node run -node <node> -command storage show fault -v
表示一个或多个风扇传感器正常、但出现故障 - 示例:
Fans:
Element Status Status Bytes Status Descriptions
(...)
11: OK 01,02,86,61 FAIL
12: OK 01,02,79,21
13: OK 01,02,6D,21
14: OK 01,02,7A,21
15: OK 01,02,74,61 FAIL
(...)
- 但是、风扇运行正常、已通过确认
system node run -node * -command environment status
- 示例:
Cooling Unit installed element list: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20; with error: none
Cooling Units by element:
[1] 6540 RPM
[2] 6390 RPM
[3] 6650 RPM
(...)
[18] 8090 RPM
[19] 8010 RPM
[20] 8000 RPM
- AutoSupport 部分
STORAGE-SHELF.XML
可能还会在 affecter NSM模块下显示错误类型Acpp