跳转到主内容

NS224 盘架上的所有路径中均缺少单个磁盘

Views:
88
Visibility:
Public
Votes:
0
Category:
fas-systems
Specialty:
hw
Last Updated:

适用于

  • ONTAP 9
  • NS224 机架

问题

  • NS224 盘架上的单个磁盘在两条路径上都丢失。
  • 如果两条路径上都缺少驱动器,则在 ONTAP 中不可见,并且绿色磁盘 LED 指示灯未亮起。
cluster1::> run -node <node name> sysconfig -a
00.1.16: NETAPP   X4013S17337T6NTE NA51 7325.4GB 4160B/sect (S60RNXXXXXXXXX) 
00.1.17: NETAPP   X4013S17337T6NTE NA51 7325.4GB 4160B/sect (S60RNXXXXXXXXX)
<No Drive 18 listed here as expected>
00.1.19: NETAPP   X4013S17337T6NTE NA51 7325.4GB 4160B/sect (S60RNXXXXXXXXX)
00.1.20: NETAPP   X4013S17337T6NTE NA51 7325.4GB 4160B/sect (S60RNXXXXXXXXX)
 
cluster1::> storage disk show
e5b.00.3.16  B    e0c.00.0.16  A     0   16
e5b.00.3.17  B    e0c.00.0.17  A     0   17
<No Drive 18 listed here as expected>
e5b.00.3.19  B    e0c.00.0.19  A     0   19
e5b.00.3.20  B    e0c.00.0.20  A     0   20
  • 系统过渡到混合路径 HA。

cluster1::> system node run -node node1 sysconfig
     NetApp Release 9.8P10: Fri Feb  4 04:27:32 EST 2022
     System ID: XXXXXXXXXX (node1); partner ID: XXXXXXXXXX (node2)
     System Serial Number: XXXXXXXXXXXX (node1)
     System Rev: A0
     System Storage Configuration: Mixed-Path HA

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.