由于SPAutoUpgradeFailedMajorAlert卡住/陈旧、服务处理器降级
适用场景
- ONTAP 9
- 服务处理器 (SP)
- 基板管理控制器(BMC)
问题描述
- SP自动升级失败、节点报告以下事件:
[node1: servprocd: sp.servprocd.upd.evts:debug]: params: {'reason': 'PostUpdate Check : SP firmware post-update check has FAILED'}
[node1: sfo_status: callhome.reboot.giveback:notice]: Call home for REBOOT (after giveback)
[node1: spmgrd: sp.heartbeat.stopped:error]: Have not received a IPMI heartbeat from the Service Processor (SP) in last 600 seconds
[node1: spmgrd: sp.heartbeat.resumed:info]: Received IPMI heartbeat from the Service Processor (SP).
[node1: nphmd: hm.alert.raised:alert]: Alert Id = SPAutoUpgradeFailedMajorAlert , Alerting Resource = SP Upgrade raised by monitor controller
- SP子系统状态已降级。
cluster1::> system health subsystem show
Subsystem Health
----------------- ------------------
SAS-connect ok
Environment ok
Memory ok
Service-Processor degraded
- 已 成功在其他节点上升级SP固件。
- 通过SSH访问SP可以正常工作。