跳转到主内容

A800上的SES固件不匹配

Views:
27
Visibility:
Public
Votes:
0
Category:
fas-systems<a>2009428540</a>
Specialty:
hw
Last Updated:

适用场景

FS4483PSM3C在AFF A800中嵌入磁盘架

问题描述

  • 节点无法确定配对节点上运行的PSM3C内部磁盘架固件的版本、反之亦然。示例

1/3/2023 10:19:30 node2 ERROR ses.mismatch.fw.version: The disk shelf modules on disk shelf 0s.0 are running two different firmware versions. Disk shelf module A is running 0140, and disk shelf module B is running .
1/3/2023 10:18:52 node1 ERROR ses.mismatch.fw.version: The disk shelf modules on disk shelf 0s.0 are running two different firmware versions. Disk shelf module A is running , and disk shelf module B is running 0140.

  • 就在这些消息之前、两个节点都会报告SES电子设备问题。示例

[node_name-01: dsa_worker2: ses.status.electronicsWarn:error]: FS4483PSM3E (S/N SHFHU0123456789) shelf 0 on channel 0s environmental monitoring warning for SES electronics 2: communication error. ; enclosure services hardware failed This element is on the rear of the shelf at the bottom, on shelf module (B).
[node_name-01: dsa_worker2: ses.status.ModuleError:alert]: FS4483PSM3E (S/N SHFHU0123456789) shelf 0 on channel 0s PCI switch error for PCI Switch 2: status not available; status not available. This element is on the rear of the shelf at the bottom, on shelf module (B).
[node_name-01: dsa_worker1: ses.status.ModuleError:alert]: FS4483PSM3E (S/N SHFHU0123456789) shelf 0 on channel 0s PCI switch error for PCI Switch 2: status not available; status not available. This element is on the rear of the shelf at the bottom, on shelf module (B).
[node_name-01: dsa_disc: ses.mismatch.fw.version:error]: The disk shelf modules on disk shelf 0s.0 are running two different firmware versions. Disk shelf module A is running 0120, and disk shelf module B is running .

[node_name-02: dsa_worker3: ses.status.electronicsWarn:error]: FS4483PSM3E (S/N SHFHU0123456789) shelf 0 on channel 0s environmental monitoring warning for SES electronics 1: communication error. ; enclosure services hardware failed This element is on the rear of the shelf at the top, on shelf module (A).
[node_name-02: dsa_worker3: ses.status.ModuleError:alert]: FS4483PSM3E (S/N SHFHU0123456789) shelf 0 on channel 0s PCI switch error for PCI Switch 1: status not available; status not available. This element is on the rear of the shelf at the top, on shelf module (A).
[node_name-02: dsa_worker0: ses.status.ModuleError:alert]: FS4483PSM3E (S/N SHFHU0123456789) shelf 0 on channel 0s PCI switch error for PCI Switch 1: status not available; status not available. This element is on the rear of the shelf at the top, on shelf module (A).
[node_name-02: dsa_disc: ses.mismatch.fw.version:error]: The disk shelf modules on disk shelf 0s.0 are running two different firmware versions. Disk shelf module A is running , and disk shelf module B is running 0120.

  • 在插槽A节点中、我们缺少PSM3C B (插槽B节点)固件版本、 sysconfig -a 反之亦然:

节点A:
    Shelf 0: FS4483PSM3E Firmware rev. PSM3E A: PSM3E B: 0140

节点B:
    Shelf 0: FS4483PSM3E Firmware rev. PSM3E A: 0140 PSM3E B:

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.